LPR Corrosion Sensors vs. Corrosion Coupons:

LPR corrosion rate monitoring is a valuable tool that can be easily and affordably deployed to provide both general and localized corrosion measurements instantly. There is a common industrial misnomer that the use of inline LPR corrosion sensors should be identical to corrosion coupons. The LPR Corrosion level represents the real-time electrochemical measurement of corrosion. Measurements gathered from the CR-301 are instant & represent “real-time conditioning” on an MPY scale based on the metallurgy being assessed.

The CR-301 corrosion rate sensor is ideal for extreme environmental and sample conditions. The sensor utilizes the linear polarization resistance (LPR) method to produce a raw signal. The raw signal is conditioned, amplified, and digitized directly in the sensor itself. This avoids the interferences and attenuation of the raw signal caused by long-distance wiring needed for other corrosion probes to a separate signal conditioner or transmitter box. The Pyxis CR-301 corrosion sensor measure sample water conductivity directly and compensate for the conductivity impact on the LPR measurement. These unique product characteristics make the Pyxis LPR superior in performance and accuracy. In addition to the LPR measurement to obtain the general corrosion rate, the CR-301 sensor also measures electrochemical noise. The measured noise data is used to calculate an index to quantify the localized corrosion rate also referred to as pitting.

Typical Applications:

  • High Temperature Applications
  • High Pressure Applications
  • Geothermal – Process
  • District Energy – Heating
  • Oil & Gas – Process & Produced Water

Features:

  • Anti-Electromagnetic Interface (anti-EMI) Design with Titanium Sensor Body
  • RS-485 Modbus Output
  • 2x 4–20mA Outputs (General & Localized Corrosion)
  • Integrated Cooling Fin Design for High Temperature Applications
  • Bluetooth® Connectivity to uPyxis® App when used with the MA-CR Adapter
  • Default 4–20mA Output Scales and Alloy Factors assigned for selected metallurgy via uPyxis®
  • Customization of Alloy Factor and Upper MPY/Index (20mA) Scale as desired via uPyxis®
  • Ultra-Low General Corrosion Rate Detection down to 0.001MPY

Specifications:

Item CR-301
Part Number 51021
General Corrosion Range – MPY 0.001-995 MPY (Default Assigned MPY is Customizable via uPyxis®)
Resolution 0.001 MPY or 1% of Reading
Localized Corrosion Range – Index 0.001-100 (Default Assigned Index is Customizable via uPyxis®)
Conductivity Compensation 10-50,000µS/cm
Reading Interval 3-1440min
Alloy Factor Range 0-3 (Adjustable Default Assigned via uPyxis® on Metallurgy UNS Code)
Power Supply 24VDC, 2W
Output RS-485 & 4-20mA
Weight 1,150g
Dimensions 280mm L x 52mm D
Installation 3/4″ NPT
Enclosure Material Titanium + PEEK
Operating Pressure Up to 500psi (34.5 Bar)
Operating Temperature -10-240 °C (14-464 °F)
Storage Temperature -20-70 °C (-4-158 °F)
Cable Format 8-Pin / 5ft (1.5m)
Protection IP68
Regulation CE + RoHS