Sidebar Sidebar Sidebar
  • Myron L 728II  ORP/Redox Digital Monitor/controller

    Myron L

    Myron L 728II ORP/Redox Digital Monitor/controller

    Advanced Circuitry The advanced “isolated” circuitry of the 720 Series II pH/ORP Monitor/ controllers guarantees accurate and reliable measurements — completely eliminating ground-loop and noise issues. The unique sensor preamp allows...

  • Myron L 727II  ORP/Redox Analog Monitor/controller

    Myron L

    Myron L 727II ORP/Redox Analog Monitor/controller

    Advanced Circuitry The advanced “isolated” circuitry of the 720 Series II pH/ORP Monitor/ controllers guarantees accurate and reliable measurements — completely eliminating ground-loop and noise issues. The unique sensor preamp allows...

  • Myron L 726II  ORP/Redox  Analog Monitor

    Myron L

    Myron L 726II ORP/Redox Analog Monitor

    Advanced Circuitry The advanced “isolated” circuitry of the 720 Series II pH/ORP Monitor/ controllers guarantees accurate and reliable measurements — completely eliminating ground-loop and noise issues. The unique sensor preamp allows...

  • Myron L 724II OEM pH Digital Monitor, Panel Mounted No Enclosure Myron L 724II OEM pH Digital Monitor, Panel Mounted No Enclosure

    Myron L

    Myron L 724II OEM pH Digital Monitor, Panel Mounted No Enclosure

    OEM = Main circuit board with meter or Liquid Crystal Display (LCD) and 12 in./305 mm Harness only. Meter comes with proper scale (Dial) decided by range selected and panel insert. LCD is Bezel style with mounting hardware for ease of panel mounting. For...

  • Myron L 721II OEM pH Analog Monitor, Panel Mounted No Enclosure Myron L 721II OEM pH Analog Monitor, Panel Mounted No Enclosure

    Myron L

    Myron L 721II OEM pH Analog Monitor, Panel Mounted No Enclosure

    OEM = Main circuit board with meter or Liquid Crystal Display (LCD) and 12 in./305 mm Harness only. Meter comes with proper scale (Dial) decided by range selected and panel insert. LCD is Bezel style with mounting hardware for ease of panel mounting. For...

  • Myron L 729II OEM ORP/Redox Digital Monitor, Panel Mounted No Enclosure Myron L 729II OEM ORP/Redox Digital Monitor, Panel Mounted No Enclosure

    Myron L

    Myron L 729II OEM ORP/Redox Digital Monitor, Panel Mounted No Enclosure

    OEM = Main circuit board with meter or Liquid Crystal Display (LCD) and 12 in./305 mm Harness only. Meter comes with proper scale (Dial) decided by range selected and panel insert. LCD is Bezel style with mounting hardware for ease of panel mounting. For...

  • Myron L 726II OEM ORP/Redox  Analog Monitor, Panel Mounted No Enclosure Myron L 726II OEM ORP/Redox  Analog Monitor, Panel Mounted No Enclosure

    Myron L

    Myron L 726II OEM ORP/Redox Analog Monitor, Panel Mounted No Enclosure

    OEM = Main circuit board with meter or Liquid Crystal Display (LCD) and 12 in./305 mm Harness only. Meter comes with proper scale (Dial) decided by range selected and panel insert. LCD is Bezel style with mounting hardware for ease of panel mounting. For...

  • Myron L CSAR Low cost Cond/TDS 75 psi @ 60°C with 1000 Ω  RTD

    Myron L

    Myron L CSAR Low cost Cond/TDS 75 psi @ 60°C with 1000 Ω RTD

    DESCRIPTION Wetted materials of construction are ABS plastic, with 316 Stainless Steel electrodes. An integral temperature element provides for automatic temperature compensation on both the CSATC and CSAR. The thermowell containing the temperature...

  • Myron L CSATC Low cost Cond/TDS 75 psi @ 60°C

    Myron L

    Myron L CSATC Low cost Cond/TDS 75 psi @ 60°C

    ZK3,476.69
    DESCRIPTION Wetted materials of construction are ABS plastic, with 316 Stainless Steel electrodes. An integral temperature element provides for automatic temperature compensation on both the CSATC and CSAR. The thermowell containing the temperature...
    ZK3,476.69

    Add to Cart The item has been added
  • Myron L CSA Low cost Cond/TDS

    Myron L

    Myron L CSA Low cost Cond/TDS

    DESCRIPTION Wetted materials of construction are ABS plastic, with 316 Stainless Steel electrodes. An integral temperature element provides for automatic temperature compensation on both the CSATC and CSAR. The thermowell containing the temperature...

  • Myron L CS60  Conductivity/TDS 100 psi @  120°C, Teflon®/Kynar®

    Myron L

    Myron L CS60 Conductivity/TDS 100 psi @ 120°C, Teflon®/Kynar®

    DESCRIPTION Wetted materials of construction are CPVC or Teflon®*/Kynar®†, with 316 Stainless Steel electrodes as standard. The  option to select other metals as electrode materials provides an unequalled chemical resistance...

  • Myron L CS50  Conductivity/TDS 100 psi @ 95°C, CPVC

    Myron L

    Myron L CS50 Conductivity/TDS 100 psi @ 95°C, CPVC

    These sensors are designed for use in general purpose applications up to approximately 20,000 µS/ppm, and provideoutstanding chemical resistance. Open front end geometry resists clogging and reduces maintenance requirements to a minimum. Wetted...

  • Myron L CS41  Conductivity/TDS or Resistivity 100 psi @ 150°C

    Myron L

    Myron L CS41 Conductivity/TDS or Resistivity 100 psi @ 150°C

    The Myron L Model CS41 sensor was designed for high pressure, high temperature Conductivity & Resistivity measurements, and is an ideal choice for boiler control applications. Blowdown control, condensate monitoring, leak detection on heat...