  • Advantage Controls Special Type Probes | DC Dip Style

    Advantage Controls

    Advantage Controls Special Type Probes | DC Dip Style

    F39,441 - F40,858
    Tank mounted probe; 190°F (87.7°C) DC probes are 18" long, CPVC construction, 212°F (100°C) max: DC-2, DC-4A, DC-2SS, DC-4ASS (SS = stainless steel sensor tips)
    F39,441 - F40,858

  • Advantage Controls Quick Release Style Advantage Controls Quick Release Style

    Advantage Controls

    Advantage Controls Quick Release Style

    F11,809 - F24,208
    E-2 and E-4A Quick Release Style PVC construction with carbon sensor tips designed for our quick release tee (T-3); 150 psi (10.4 bar), 140°F (60°C) max: E-2, E-4A, E-2SS, E-4ASS (SS = stainless steel sensor tips).
    F11,809 - F24,208

  • Advantage Controls Optical Leak Detection Sensor

    Advantage Controls

    Advantage Controls Optical Leak Detection Sensor

    F45,109
    Application: The general purpose of the optic leak switch is to provide reliable leak detection in and around secondary containment, tanks, pumps, and piping systems with a 1A relay dry contact output. The dry contact relay can be connected to a...
    F45,109

    Add to Cart The item has been added
  • Advantage Controls LS200 Level Sensor

    Advantage Controls

    Advantage Controls LS200 Level Sensor

    F61,286 - F66,482
    Application: The general-purpose ultrasonic sensor provides non-contacting level measurement from 4” (0.1m) to 78” (1.9m) with a 4-20mA output.The four-wire sensor requires a 24 VDC power supply and will work for signal distances up to 1000...
    F61,286 - F66,482

  • Advantage Controls EchoPod Drum Level Sensors

    Advantage Controls

    Advantage Controls EchoPod Drum Level Sensors

    F48,651 - F72,623
    Application: The general purpose ultrasonic sensor provides non-contacting level measurement up to 49" (124 cm) or 9.8" (3 m) with a 4-20mA output. The two-wire 4-20mA output requires a 24 VDC loop power supply and will work for signal distances up to...
    F48,651 - F72,623

  • Advantage Controls Free Chlorine & CLO2 Sensors

    Advantage Controls

    Advantage Controls Free Chlorine & CLO2 Sensors

    F78,409 - F345,282
    Specifications: Operating Temp Range: 32-113°F (0-45°C) Operating Pressure: 14.7 psi (1 bar) max Flow Rate: 0.2 GPM (0.75 LPM) min, 0.6 GPM (2.25 LPM) max pH Range: 6.5-8.0 Output Signal: 4.0+/- 0.2mA in air (zero) 20mA +/- 0.2mA at high...
    F78,409 - F345,282

  • Little Dipper 2 Fluorometer by Turner Designs

    Advantage Controls

    Little Dipper 2 Fluorometer by Turner Designs

    F205,469 - F218,694
    Application: The Turner Designs Little Dipper 2 in-line fluorometer is a compact sensor designed for monitoring and control of fluorescent dyes in industrial water systems with a single 4-20mA analog output. Advantage Controls’ makes integration simple...
    F205,469 - F218,694

  • Advantage Controls Hand-held Simulator

    Advantage Controls

    Advantage Controls Hand-held Simulator

    F41,802
    Application: Advantage Controls new HanTron series of handheld signal simulators provide a convenient means of testing and calibrating multiple instrumentation signals. The HanTron signal simulator provides an efficient method for calibrating current...
    F41,802

  • Advantage Controls Boiler Solenoid Valves | SGB

    Advantage Controls

    Advantage Controls Boiler Solenoid Valves | SGB

    F50,659 - F55,854
    Specifications: Max Fluid Temp: 350°F Max Boiler Pressure: 13-140 PSIG Valve Body: Brass Seals: Teflon Shipping Weight: 3 lbs. Standard Electrical: 120 VAC Sizes Available: 1/2” & 3/4”
    F50,659 - F55,854

  • Advantage Controls Boiler Solenoid Valves | SOB

    Advantage Controls

    Advantage Controls Boiler Solenoid Valves | SOB

    F85,966 - F99,074
    Specification: Max Fluid Temp: 356°F Max Boiler Pressure: 140 PSIG Valve Body: Brass Seals: Teflon Shipping Weight: 3 lbs Standard Electrical: 120 VAC Sizes Available: 1/2" & 3/4"
    F85,966 - F99,074

  • Neptune Polymaster Standard Manual Models

    Neptune

    Neptune Polymaster Standard Manual Models

    F1,254,303 - F1,442,531
    Polymaster™ - Polymer Activation and Blending System Neptune Polymaster™ dilutes, mixes and thoroughly activates emulsion, dispersion and solution polymers, including new high-molecular-weight products. Polymaster provides state-of-the-art...
    F1,254,303 - F1,442,531

  • Walchem LKN57X LK Series Motor Driven Metering Pumps

    Walchem

    Walchem LKN57X LK Series Motor Driven Metering Pumps

    F295,922 - F789,873
    The LK Series metering pump is the largest in the high performance line of pumps from Walchem. The LK is a motor-driven, mechanically actuated diaphragm metering pump with a maximum capacity of 114 GPH (432 l/h) and a maximum pressure of 225 PSI (1.5...
    F295,922 - F789,873

  • BW U-300 Pitot Tube Acrylic Flow Meter, upflow BW U-300 Pitot Tube Acrylic Flow Meter, upflow

    Blue-White

    BW U-300 Pitot Tube Acrylic Flow Meter, upflow

    F16,414
    Pitot Tube Acrylic Flow Meter An aquatics industry standard for over six decades, Blue-White’s F-300 Flow Meter is accurate and has reduced space requirements for installation. The aerodynamic pitot tube is designed for smooth fluid flow through...
    F16,414

  • BW D-300 Pitot Tube Acrylic Flow Meter, downflow BW D-300 Pitot Tube Acrylic Flow Meter, downflow

    Blue-White

    BW D-300 Pitot Tube Acrylic Flow Meter, downflow

    F16,414
    Pitot Tube Acrylic Flow Meter An aquatics industry standard for over six decades, Blue-White’s F-300 Flow Meter is accurate and has reduced space requirements for installation. The aerodynamic pitot tube is designed for smooth fluid flow...
    F16,414