Pyxis
Pyxis
Pyxis IK-765SS-O3 Ozone + pH Panel Solution
The IK-765SS-O3 is a dual-parameter inline water analyzer specifically designed as a ‘Turn-Key’ monitoring solution for clean water applications including bottled water production, drinking water networks, secondary water supply and alternative clean-water ozone treatment applications. The IK-765SS-O3 offers highly accurate, real-time measurement, display and data-logging of Ozone (O3), pH and Temperature utilizing proprietary Pyxis Lab smart sensor technology, coupled with a Pyxis UC-80 touch screen display and data logging terminal. The IK-765 series is offered in a convenient and easy to integrate panel mounted format for rapid installation and simple maintenance.
The IK-765 Ozone analyzer is equipped with the propriety Pyxis ST- 765SS-O3 smart sensor design which is membrane-free and based on unique principles and incorporates Pyxis’ advanced technology in the field of bare-gold electrochemical detection. The sensor measures the Ozone level and pH simultaneously while performing temperature and pH compensation for the measurement of oxidant based on conditions present in the application of use. The IK-765SS-O3 panel is also provided with the ST-007 stainless steel flow reservoir with inlet rotameter, digital flow meter and UC-80 display/data logging terminal prewired to the sensor in RS-485 modbus format with fully integrated sensor diagnostics and calibration interface.
This unique platform with internal sensor compensation and self-cleaning results in a highly accurate ozone measurement consistent with DPD wet chemistry methodology as high as pH 9.0+ and meets EPA-334.0 and ISO-7393 compliance.
Turn-Key Installation
All Pyxis IK-765 series analyzers require a small installation footprint, offer simple operation and maintenance and are specifically designed for use in commercial water and beverage bottling, domestic and drinking water applications. The analyzer may also be integrated with the optional Pyxis PowerCloud™ 4G remote gateway, which can upload on-site analyzer data to a cloud server in real time and allow for additional sensor /device inputs for cloud access. Contact Pyxis Lab for details on PowerCloud™ and Pyxis Cloud™.
Typical Applications
- Bottled Water Post Ozone – Pre Filler
- Spring Water Offload
- Drinking Water and Domestic Water
- Sanitary Water
- Decorative Water
- Food & Beverage Process Water
Features
- Pyxis Lab’s advanced research and development sensor technologies to achieve highly accurate and stable measurement of Ozone, pH and Temperature.
- Pyxis ST-765SS-O3 is a three-parameter composite sensor used for the measurement residual ozone, pH and temperature in compliance with USEPA 334.0 and ISO-7393 guidelines. In addition, the sensors advanced PCB offers built-in temperature and pH parameter compensation (up to pH 9.0+) algorithms eliminating the need for a supplemental pH sensor and controller. Furthermore, unique Bare-Gold electrode technology for ozone measurement eliminates membranes and electrode solution replenishment commonly associated with conventional sensors. The ST-765SS Series has a uniquely designed flat bubble pH electrode design for reduced fouling potential. Reduce your maintenance and cost versus conventional electrochemical sensors by utilizing Pyxis replaceable Electrode Head (EH-765) for this sensor allowing for years of reliable service. Therefore, the ST-765SS Series may be calibrated in-situ after cleaning via DPD or similar Ozone wet chemistry test measurement of active sample.
- Pyxis ST-007 Single-Sensor inline stainless steel flow cell provides an ozone demand-free environment for the safe installation and accurate operation of the ST-765SS-O3 sensor. The inlet and outlet to the ST-007 are 316L stainless steel with SwageLok fittings in ¼-inch OD. The IK-765SS-O3 panel is also equipped with inlet PRV, Rotameter and digital Hall Effect inlet flow meter for precise control and recording of the recommended flow range of 200-400 mL /minute. The outlet flow should be diverted to drain or the inlet of the pretreatment system for those desiring NSF compliance.
Convenience
-
Simple sensor removal and replacement. The ST-765SS Series sensors are connected to the display /data logger via RS-485 modbus (RTU) allowing for integrated sensor calibration interface and diagnostics within the display screen.
-
Convenient and simple to install Back-Panel (IK-765) for rapid and easy installation. Truly a plumb and power to go platform with intense factory setup, testing and sensor calibration prior to shipment.
-
UC-80 touch screen color display /data logger prewired to the Pyxis sensor via RS-485 with calibration interface. Display/data logger offers 2x 4-20mA, RS-485 and TCP Modbus output with remote diagnosis and parameter adjustment. Pyxis PowerCloudTM 4G Gateway available as an optional accessory.
Specifications
Item | IK-765SS-O3 |
Part Number | 42091 |
Sensor Body Material | 304SS |
Ozone Range | 0.01–2.00ppm Ozone (Auto-Range) |
pH Range | 0–14 |
Ozone Precision | ±1.0mg/L or 1% of the Value with pH compensation up to 9.0+ |
pH Precision | ±0.01 |
Sample Operating Temperature | 4-40 °C (40-104 °F) |
Sample Inlet Pressure | 7.25-30psi (0.05-0.2MPa) |
Sensor Max Pressure | 100psi (6.9Bar) |
Sensor Response Time | T95≤60s – Oxidizer / T95≤5s pH |
Measurement Interval | Continuous |
Installation | ST-007 (316L) Flow Cell with PRV-Rotameter – Hall Effect Flow Meter Included |
ST-007 Min Flow Rate | 200mL/min |
ST-007 Max Flow Rate | 400mL/min |
ST-007 Sample Inlet | 1/4inch OD |
ST-007 Sample Outlet | 1/4 inch OD |
Panel Power Supply | 96–260VAC / 50-60Hz; 200W |
Panel Storage Temperature | -4–158 ºF (-20–70 ºC) |
Panel Operational Temperature | 32–122 ºF (0–50 ºC) |
UC-80 Display | 4.3inch LCD Color 480×272 Pixel Resolution / Resistive Touch |
UC-80 Input | RS-485 Modbus – RTU |
UC-80 Output | (2) 4-20mA / RS-485 Modbus RTU / Modbus-TCP |
UC-80 Data Storage | Built-In 1GB of RAM for Storing up to 1-Million Data/Event Records |
UC-80 USB | (1) USB Host for Data Downloading and Screen Upgrade |
UC-80 Relative Humidity | 20–90% (No Condensation) |
UC-80 Altitude | <6,561ft (<2,000m) |
Dimension (HxWxD) | 440H x 350W x 153D mm |
Approx. Weight | 15kg |
Wet Material | 316L Stainless Steel / Polycarbonate |
Rating | IP-65 Panel Display / IP-65 Sensor |
Selectivity | Non-Selective / Cross Sensitive to other Oxidizing Species |
Compliance | EPA 334.0 / ISO-7393 |
Regulation | CE Marked / RoHS |
Typical Electrode Service Life | 2 Years |
Electrode Warranty | 6 Months |
Sensor Body Warranty | 13 Months |