Lakewood Instruments

Lakewood Instruments NexSys Boiler Water Treatment Controller

No reviews yet
SKU: NXB
Weight: 1.00 LBS

Call For Quote 1 (916) 315-2691

  • product-security-image-1.jpg
  • product-security-image-2.jpg
  • product-security-image-3.jpg
  • product-security-image-4.jpg

NexSys Boiler and Cooling Tower Water Treatment Controller Overview

  • Each unit can control up to 2 cooling towers or up to 4 boilers simultaneously – lowering your capital cost for the entire site.
  • Building Management System connectivity.
  • You determine the inputs you need for your system, including: Conductivity, pHORP, Water MetersFlow SwitchesTrace Chemistry, and any 4-20 mA input.
  • Six output relays are standard, and every NexSys may be expanded to ten output relays total.
  • Sensor inputs connect to Smart Nodes – small circuit boards in a compact design. 
  • The nodes become an internal NexSys network that expands as you need it.
  • The nodes can be located as much as 400 meters / 1300 feet from the NexSys controller– giving you flexibility and leveraging the power of this datalog water treatment controller.

NexSys Boiler and Cooling Tower Controller Updates

  • In late 2020, Lakewood updated the graphical interface for the NexSys systems, giving a more modern appearance, and clarity to the user experience.
  • We have also made some simplifications in the BACnet/IP interface, eliminating the need for external components for Building Management System integration.

Standard Features

  • Color touch screen.
  • Datalogging.
  • Onboard graphs.
  • Six output relays expandable to ten output relays for user configurable operations such as:
    • Feed by percent of blowdown time
    • Feed by setpoint with percent of time feature as part of spaced feed
    • Trace chemistry control
    • By makeup totalized gallons
    • By blowdown totalized gallons
    • By percent on-time
    • By scheduled feed by day and time
  • Up to eight active 4-20mA input readings
    • 2 tower conductivity inputs
    • 2 makeup conductivity inputs
    • pH and ORP inputs
  • Two flow switch inputs configurable to any relay output
  • Two water meter inputs with field expansion capability to four

Additional Features

  • LonWorks, MODbus, and BACnet communications interface
  • Ethernet capability through an HTML interface
  • The capability to send E-service reports to a subscribed service
  • The ability to display operating values with time and date stamps on color coded graphs with zoom and scroll features
  • Trace chemistry capable
  • Enclosure is NEMA 4X rated
  • Ability to add four digital inputs
  • Ability to mount every sensor/input up to 400 meters away from the controller via 4-wire twisted pair
  • Ability to provide complete water quality control for two cooling towers or up to four (4) boilers at the same time
  • On-board help screens with wiring, programming and maintenance instructions
  • Left or right exit plumbing assemblies available

Specifications

  • Type: NexSys Dual Control System
  • Conductivity Sensor: Optional conductivity sensor
  • pH Sensor: Optional pH sensor
  • ORP Sensor: Optional ORP sensor
  • Make-up Conductivity: Optional make-up conductivity sensor
  • Output Relays: Optional relays
  • Flow Switch: Optional flow switch
  • Water Meter: Optional water meter
  • Analog Input: Optional 4-20 mA input
  • Output Signal: Optional 4-20 mA output signal
  • Remote Display: No remote display
  • Mounting plate: Optional mounting plate
  • Conductivity Range: 0 – 5,000 μS
  • Maximum Pressure: 140 psi (9.65 bar) @ 100 °F
  • Process Temperature: Max 140°F (60°C)
  • Ambient Temperature: -4° to 158°F (-20° to 70°C)
  • Conductivity Resolution: 10 μS
  • Conductivity Accuracy: ± 40 μS
  • pH Range: 2-12 pH
  • pH Accuracy: ± 0.05 pH
  • pH Resolution: 0.01 pH
  • ORP Range: -1000 to +1000 mV
  • ORP Accuracy: ± 5.0 mV
  • ORP Resolution: 1 mV
  • Accuracy & Repeatability: ± 1.0% of scale
  • Deadband/Setpoint: User programmable
  • Enclosure: NEMA 4X, ETL
  • Timer: Relay run time exceeded
  • Power: 120/240 VAC 50/60 Hz
  • Relay Ratings: 120VAC 3A each, 15A total

Downloads

CutSheet: NexSys Boiler Water Treatment Controller

Quick Start Guide: NexSys Boiler Water Treatment Controller

Product Manual: NexSys Boiler Water Treatment Controller

Product Manual: NexSys Boiler Water Treatment Controller – Legacy Graphics (Pre-2021)

Customers Also Viewed