Pyxis

Pyxis ST-588SS | High Pressure Fluorescent Polymer + PTSA Inline Sensor

No reviews yet
SKU: 50693
Weight: 0.37 LBS
Shipping: Calculated at Checkout
BD1,221.117
icon Share icon Share
  • product-security-image-1.jpg
  • product-security-image-2.jpg
  • product-security-image-3.jpg
  • product-security-image-4.jpg

Checkout securely with:

Description:

The Pyxis ST-588 inline fluorometer sensor simultaneously measures the concentration of PTSA and Fluo-rescent Polymer in water. It can be simply inserted to the compression fitting port of a custom-made tee.The standard ST-001 installation tee provided with each ST-588 sensor, has two ¾ inch female NPT ports andcan be placed to an existing ¾ inch sample water line. Pyxis Lab also offers 2" and 3" Tee formats for largerflow installations. The 4–20mA current output of the ST-588 sensor can be connected to any controllerthat accepts an isolated or non-isolated 4–20mA input. The ST-588 sensor is a smart device. In additionto measuring PTSA and Fluorescent Polymer, the ST-588 sensor has extra photo-electric components thatmonitor the color and turbidity of the sample water. This extra feature allows automatic color and turbiditycompensation to eliminate interference commonly associated with real-world waters.The Pyxis ST-588 sensor has a short fluidic channel and can be easily cleaned. The fluidic and optical ar-rangement of the ST-588 sensor is designed to overcome shortcomings associated with other fluorometersthat have a distal sensor surface or a long, narrow fluidic cell. Traditional inline fluorometers are susceptibleto color and turbidity interference and fouling and are difficult to properly clean.

Features:

The ST-588 measures PTSA and Fluorescent Polymer in a water sample and includes the following features:

  • Easy calibration with using uPyxis® Mobile or Desktop App.
  • Automatic compensation for turbidity up to 150 NTU and color created by up to 10 ppm iron or
  • equivalent to 10 ppm humic acid.
  • Diagnostic information (sensor fouling, color or turbidity over range, failure modes) are available in
  • uPyxis® App or via Modbus RTU.
  • Easy to remove from the system for cleaning and calibration without the need for any tools.

Specifications:

Specification

ST-588SS

Part Number (P/N)

50693

Fluorescent Polymer Range

† 0.0–20.0 ppm

Fluorescent Polymer Accuracy

±0.1 ppm

PTSA Range

0.0–200.0 ppb

PTSA Accuracy

±1 ppb

Excitation Wavelength

410 nm (Fluorescent Polymer) 365 nm (PTSA)

Emission Wavelength

450 nm (Fluorescent Polymer) 410 nm (PTSA)

Wavelength Accuracy

±1 nm

Calibration

Two-point calibration against standard solution

Outputs

2x 4–20mA Analog Output, RS-485 Digital Output with Modbus protocol

Installation

3/4” FNPT threaded ports

Cable Length

5 ft with IP67 connectors & 1.5 ft flying lead with IP67 adapter

Power Supply

22–26 VDC, 1.8 W

Dimension

(L × Dia) ‡ 6.8 × 1.44 inch (172.7 × 36.6 mm)

Weight

0.37 lbs (170 g) 2.5 lbs (1148 g)

Material

304 Stainless Steel

Operational Temperature

40–104 °F (4–40 °C)

Storage Temperature

20–140 °F (-7–60 °C)

Pressure

Up to 290 psi (2.0 MPa)

Enclosure Rating

IP67

Regulation

CE

Customers Also Viewed