Cooling Tower Contacting Conductivity Sensors

Sidebar Sidebar Sidebar
  • Walchem WCT600 Cooling Tower Controller Walchem WCT600 Cooling Tower Controller

    Walchem

    Walchem W600-CT Cooling Tower Controller

    Cooling towers are used in various industrial processes to lower temperature of water stream. There are several factors that help ensure the performance of these devices. Conductivity, level of dissolved solids, corrosion inhibitor, feed inhibitor, and...

  • 191638-20 Walchem Sensor, Electrodeless Conductivity, CPVC, 20 ft. cable

    Walchem

    191638-20 Walchem Sensor, Electrodeless Conductivity, CPVC, 20 ft. cable

    Дин42.138,57
    Electrodeless conductivity sensors measure conductivity of a solution utilizing encapsulated, non-contacting, toroidal technology. They may be installed in a variety of very harsh chemical control applications, including oily cleaner baths, chromates,...
    Дин42.138,57

    Add to Cart The item has been added
  • Walchem Contacting Conductivity Sensor 3 ft. Cable

    Walchem

    191647-03 Walchem Sensor, Contacting Conductivity, PP/SS, 3 ft. cable

    Дин18.107,29
    These cell constant 1.0 sensors are designed for cooling towers with water up to 30,000 μS/cm (range varies with solution temperature, see next page). Lower pressure (up to 150 PSI, 10 bar) polypropylene sensors are available with graphite or...
    Дин18.107,29

    Add to Cart The item has been added
  • Walchem Contacting Conductivity Sensor 20 ft. Cable

    Walchem

    191647-20 Walchem Sensor, Contacting Conductivity, PP/SS, 20 ft. cable

    Дин18.107,29
    These cell constant 1.0 sensors are designed for cooling towers with water up to 30,000 μS/cm (range varies with solution temperature, see next page). Lower pressure (up to 150 PSI, 10 bar) polypropylene sensors are available with graphite or...
    Дин18.107,29

    Add to Cart The item has been added
  • Walchem Contacting Conductivity Sensor

    Walchem

    191693-10 Walchem Sensor, Contacting Conductivity, 300 psi, 10 ft. cable

    Дин76.117,69
    Walchem 191693-10 Chemical Metering Pump Repair Part - Sensor, Contacting Conductivity, 300 psi, 10 ft. cable. This sensor is specifically crafted for measuring contacting conductivity, with a durable design capable of handling pressures up to 300 pounds...
    Дин76.117,69

    Add to Cart The item has been added
  • 191646-03 Walchem Sensor, Contacting Conductivity, PP/Graphite, 3 ft. cable

    Walchem

    191646-03 Walchem Sensor, Contacting Conductivity, PP/Graphite, 3 ft. cable

    Дин18.107,29
    Cooling Tower Contacting Conductivity Sensors These cell constant 1.0 sensors are designed for cooling towers with water up to 30,000 μS/cm (range varies with solution temperature, see next page). Lower pressure (up to 150 PSI, 10 bar) polypropylene...
    Дин18.107,29

    Add to Cart The item has been added
  • Walchem Contacting Conductivity Sensor

    Walchem

    191646-20 Walchem Sensor, Contacting Conductivity, PP/Graphite, 20 ft. cable

    Дин18.107,29
    Walchem 191646-20 Chemical Metering Pump Repair Part - Sensor, Contacting Conductivity, PP/Graphite, 20 ft. cable. This sensor is specifically engineered for measuring contacting conductivity and features a construction with polypropylene (PP) and...
    Дин18.107,29

    Add to Cart The item has been added