Pulsation Dampeners

Pulsations in a fluid flow can cause problems in piping systems, such as valve erosion, and vibration. A pulsation dampener is a pumping accessory that helps overcome these challenges and optimize the performance of your pumping systems.

A pulsation dampener is an equipment that is used in fluid systems to reduce pressure fluctuations or pulsations resulting from reciprocating pumps, compressors, or other pulsating flow sources. This ensures a smoother and more consistent flow. These dampeners reduce pulsation that can otherwise create problems in piping systems, such as vibration and valve erosion.

Sidebar Sidebar Sidebar
  • sale
    Pulsafeeder NA603675-PVDC Pulsation Dampeners, 3/4" FNPT

    Pulsafeeder

    Pulsafeeder NA603675-PVDC Pulsation Dampeners, 3/4" FNPT

    FRw3775175
    FRw3208899
    Pulsafeeder’s Pulsation Dampeners improve pump system efficiency by removing pulsating flows from piston, plunger, air diaphragm, peristaltic, gear, or diaphragm metering pump insuring a smooth continuous fluid flow and metering accuracy,...
    FRw3775175
    FRw3208899

    Add to Cart The item has been added
  • sale
    Pulsafeeder NA603675-FPPT Pulsation Dampeners, 3/4" FNPT

    Pulsafeeder

    Pulsafeeder NA603675-FPPT Pulsation Dampeners, 3/4" FNPT

    FRw4516930
    FRw3839399
    Pulsafeeder’s Pulsation Dampeners improve pump system efficiency by removing pulsating flows from piston, plunger, air diaphragm, peristaltic, gear, or diaphragm metering pump insuring a smooth continuous fluid flow and metering accuracy,...
    FRw4516930
    FRw3839399

    Add to Cart The item has been added
  • sale
    Pulsafeeder NA603675-FPPC Pulsation Dampeners, 3/4" FNPT

    Pulsafeeder

    Pulsafeeder NA603675-FPPC Pulsation Dampeners, 3/4" FNPT

    FRw2425096
    FRw2061332
    Pulsafeeder’s Pulsation Dampeners improve pump system efficiency by removing pulsating flows from piston, plunger, air diaphragm, peristaltic, gear, or diaphragm metering pump insuring a smooth continuous fluid flow and metering accuracy,...
    FRw2425096
    FRw2061332

    Add to Cart The item has been added
  • sale
    Pulsafeeder NA603675-316V Pulsation Dampeners, 3/4" FNPT

    Pulsafeeder

    Pulsafeeder NA603675-316V Pulsation Dampeners, 3/4" FNPT

    FRw5431388
    FRw4616688
    Pulsafeeder’s Pulsation Dampeners improve pump system efficiency by removing pulsating flows from piston, plunger, air diaphragm, peristaltic, gear, or diaphragm metering pump insuring a smooth continuous fluid flow and metering accuracy,...
    FRw5431388
    FRw4616688

    Add to Cart The item has been added
  • sale
    Pulsafeeder NA603675-316T Pulsation Dampeners, 3/4" FNPT

    Pulsafeeder

    Pulsafeeder NA603675-316T Pulsation Dampeners, 3/4" FNPT

    FRw7235227
    FRw6149943
    Pulsafeeder’s Pulsation Dampeners improve pump system efficiency by removing pulsating flows from piston, plunger, air diaphragm, peristaltic, gear, or diaphragm metering pump insuring a smooth continuous fluid flow and metering accuracy,...
    FRw7235227
    FRw6149943

    Add to Cart The item has been added
  • sale
    Pulsafeeder NA603675-316E Pulsation Dampeners, 3/4" FNPT

    Pulsafeeder

    Pulsafeeder NA603675-316E Pulsation Dampeners, 3/4" FNPT

    FRw4637586
    FRw3941948
    Pulsafeeder’s Pulsation Dampeners improve pump system efficiency by removing pulsating flows from piston, plunger, air diaphragm, peristaltic, gear, or diaphragm metering pump insuring a smooth continuous fluid flow and metering accuracy,...
    FRw4637586
    FRw3941948

    Add to Cart The item has been added
  • sale
    Pulsafeeder NA603675-316C Pulsation Dampeners, 3/4" FNPT

    Pulsafeeder

    Pulsafeeder NA603675-316C Pulsation Dampeners, 3/4" FNPT

    FRw4763604
    FRw4049071
    Pulsafeeder’s Pulsation Dampeners improve pump system efficiency by removing pulsating flows from piston, plunger, air diaphragm, peristaltic, gear, or diaphragm metering pump insuring a smooth continuous fluid flow and metering accuracy,...
    FRw4763604
    FRw4049071

    Add to Cart The item has been added
  • sale
    Pulsafeeder NA601050-PVCV Pulsation Dampeners, 1/2" FNPT

    Pulsafeeder

    Pulsafeeder NA601050-PVCV Pulsation Dampeners, 1/2" FNPT

    FRw1312384
    FRw1115535
    Pulsafeeder’s Pulsation Dampeners improve pump system efficiency by removing pulsating flows from piston, plunger, air diaphragm, peristaltic, gear, or diaphragm metering pump insuring a smooth continuous fluid flow and metering accuracy,...
    FRw1312384
    FRw1115535

    Add to Cart The item has been added
  • sale
    Pulsafeeder NA601050-PVCT Pulsation Dampeners, 1/2" FNPT

    Pulsafeeder

    Pulsafeeder NA601050-PVCT Pulsation Dampeners, 1/2" FNPT

    FRw2428566
    FRw2064281
    Pulsafeeder’s Pulsation Dampeners improve pump system efficiency by removing pulsating flows from piston, plunger, air diaphragm, peristaltic, gear, or diaphragm metering pump insuring a smooth continuous fluid flow and metering accuracy,...
    FRw2428566
    FRw2064281

    Add to Cart The item has been added
  • sale
    Pulsafeeder NA601050-FPPV Pulsation Dampeners, 1/2" FNPT

    Pulsafeeder

    Pulsafeeder NA601050-FPPV Pulsation Dampeners, 1/2" FNPT

    FRw1434933
    FRw1219693
    Pulsafeeder’s Pulsation Dampeners improve pump system efficiency by removing pulsating flows from piston, plunger, air diaphragm, peristaltic, gear, or diaphragm metering pump insuring a smooth continuous fluid flow and metering accuracy,...
    FRw1434933
    FRw1219693

    Add to Cart The item has been added
  • sale
    Pulsafeeder NA601050-FPPT Pulsation Dampeners, 1/2" FNPT

    Pulsafeeder

    Pulsafeeder NA601050-FPPT Pulsation Dampeners, 1/2" FNPT

    FRw2299078
    FRw1954224
    Pulsafeeder’s Pulsation Dampeners improve pump system efficiency by removing pulsating flows from piston, plunger, air diaphragm, peristaltic, gear, or diaphragm metering pump insuring a smooth continuous fluid flow and metering accuracy,...
    FRw2299078
    FRw1954224

    Add to Cart The item has been added
  • sale
    Pulsafeeder NA601050-FPPC Pulsation Dampeners, 1/2" FNPT

    Pulsafeeder

    Pulsafeeder NA601050-FPPC Pulsation Dampeners, 1/2" FNPT

    FRw1202769
    FRw1022354
    Pulsafeeder’s Pulsation Dampeners improve pump system efficiency by removing pulsating flows from piston, plunger, air diaphragm, peristaltic, gear, or diaphragm metering pump insuring a smooth continuous fluid flow and metering accuracy,...
    FRw1202769
    FRw1022354

    Add to Cart The item has been added
  • sale
    Pulsafeeder NA601038-PVDV Pulsation Dampeners, 3/8" FNPT

    Pulsafeeder

    Pulsafeeder NA601038-PVDV Pulsation Dampeners, 3/8" FNPT

    FRw1682079
    FRw1429775
    Pulsafeeder’s Pulsation Dampeners improve pump system efficiency by removing pulsating flows from piston, plunger, air diaphragm, peristaltic, gear, or diaphragm metering pump insuring a smooth continuous fluid flow and metering accuracy,...
    FRw1682079
    FRw1429775

    Add to Cart The item has been added
  • sale
    Pulsafeeder NA601038-PVDT Pulsation Dampeners, 3/8" FNPT

    Pulsafeeder

    Pulsafeeder NA601038-PVDT Pulsation Dampeners, 3/8" FNPT

    FRw2932637
    FRw2492742
    Pulsafeeder’s Pulsation Dampeners improve pump system efficiency by removing pulsating flows from piston, plunger, air diaphragm, peristaltic, gear, or diaphragm metering pump insuring a smooth continuous fluid flow and metering accuracy,...
    FRw2932637
    FRw2492742

    Add to Cart The item has been added
  • sale
    Pulsafeeder NA601038-PVDE Pulsation Dampeners, 3/8" FNPT

    Pulsafeeder

    Pulsafeeder NA601038-PVDE Pulsation Dampeners, 3/8" FNPT

    FRw1560635
    FRw1326548
    Pulsafeeder’s Pulsation Dampeners improve pump system efficiency by removing pulsating flows from piston, plunger, air diaphragm, peristaltic, gear, or diaphragm metering pump insuring a smooth continuous fluid flow and metering accuracy,...
    FRw1560635
    FRw1326548

    Add to Cart The item has been added
  • sale
    Pulsafeeder NA601038-PVDC Pulsation Dampeners, 3/8" FNPT

    Pulsafeeder

    Pulsafeeder NA601038-PVDC Pulsation Dampeners, 3/8" FNPT

    FRw1560635
    FRw1326548
    Pulsafeeder’s Pulsation Dampeners improve pump system efficiency by removing pulsating flows from piston, plunger, air diaphragm, peristaltic, gear, or diaphragm metering pump insuring a smooth continuous fluid flow and metering accuracy,...
    FRw1560635
    FRw1326548

    Add to Cart The item has been added
  • sale
    Pulsafeeder NA601038-FPPV Pulsation Dampeners, 3/8" FNPT

    Pulsafeeder

    Pulsafeeder NA601038-FPPV Pulsation Dampeners, 3/8" FNPT

    FRw1433355
    FRw1218352
    Pulsafeeder’s Pulsation Dampeners improve pump system efficiency by removing pulsating flows from piston, plunger, air diaphragm, peristaltic, gear, or diaphragm metering pump insuring a smooth continuous fluid flow and metering accuracy,...
    FRw1433355
    FRw1218352

    Add to Cart The item has been added
  • sale
    Pulsafeeder NA601038-FPPT Pulsation Dampeners, 3/8" FNPT

    Pulsafeeder

    Pulsafeeder NA601038-FPPT Pulsation Dampeners, 3/8" FNPT

    FRw2306491
    FRw1960517
    Pulsafeeder’s Pulsation Dampeners improve pump system efficiency by removing pulsating flows from piston, plunger, air diaphragm, peristaltic, gear, or diaphragm metering pump insuring a smooth continuous fluid flow and metering accuracy,...
    FRw2306491
    FRw1960517

    Add to Cart The item has been added
  • sale
    Pulsafeeder NA601038-FPPE Pulsation Dampeners, 3/8" FNPT

    Pulsafeeder

    Pulsafeeder NA601038-FPPE Pulsation Dampeners, 3/8" FNPT

    FRw1128799
    FRw959487
    Pulsafeeder’s Pulsation Dampeners improve pump system efficiency by removing pulsating flows from piston, plunger, air diaphragm, peristaltic, gear, or diaphragm metering pump insuring a smooth continuous fluid flow and metering accuracy,...
    FRw1128799
    FRw959487

    Add to Cart The item has been added
  • sale
    Pulsafeeder NA601038-FPPC Pulsation Dampeners, 3/8" FNPT

    Pulsafeeder

    Pulsafeeder NA601038-FPPC Pulsation Dampeners, 3/8" FNPT

    FRw1128799
    FRw959487
    Pulsafeeder’s Pulsation Dampeners improve pump system efficiency by removing pulsating flows from piston, plunger, air diaphragm, peristaltic, gear, or diaphragm metering pump insuring a smooth continuous fluid flow and metering accuracy,...
    FRw1128799
    FRw959487

    Add to Cart The item has been added

At Cannon Water Technology, we offer the finest quality pulsation dampeners that effectively minimize pulsations and guarantee stable discharge flow and pressure. With us, you can get the most appropriate model based on the type of liquid being pumped, piping configuration, pressure and flow rate, and mounting requirements.

Working Principles of Pulsation Dampeners for Dosing Pumps

Here's a step-by-step breakdown of how pulsation dampeners work to stabilize fluid flow.

  1. Pressure equalization: Pulsation dampeners apply balanced pressure to each pump stroke, especially during low-pressure points, ensuring consistent operation.
  2. Absorbing pulsations: As a diaphragm pump creates pressure pulsations, the dampener's internal component (often a flexible bladder or diaphragm) expands and contracts, responding dynamically to changes in pressure.
  3. Smoothing peaks and troughs: During high-pressure peaks, the dampener absorbs excess energy; during low-pressure troughs, it releases stored energy, thus almost equalizing flow variations.
  4. Reducing fluctuations and noise: By minimizing pressure fluctuations, dampeners reduce vibrations and noise, enhancing equipment stability and performance while also extending the operating life of the pump.

Components of Pulsation Dampener

All types of pulsation dampeners may vary in size, shape, and materials, but they have some common parts. These parts help keep the flow of liquid steady, which is important for the system's stability and longevity. The main components include:

  1. Pressure vessel: The pressure vessel is the primary part of the pulsation dampener. It consists of different components and can withstand the pressures experienced during pumping. The materials and design of the pressure vessel are key to making the dampener safe and durable.
  2. Diaphragm: In a pulsation dampener, the diaphragm separates the liquid from the dampening element and the environment. It has flexible properties that enable the inner volume of the pulsation damper to differ. At Cannon Water Technology, you have the option to choose among different diaphragm materials, such as EPDM or FFKM, to achieve chemical compatibility.
  3. Dampening element: The dampening element is a solid part located just outside the diaphragm. It absorbs and reduces pressure changes. The special material can expand and contract, which helps counteract pressure spikes and keeps the flow rate steady and consistent.
  4. Inlet and outlet connection: These connections attach the pulsation dampener to the pump system. It's important to size and position these connections correctly to reduce pulsations and create an effective dampening effect.

Features of Pulsation Dampener

There are many reasons to purchase a pulsation dampener for your pumps. This pumping accessory can reduce noise levels by up to 90%. This can be highly beneficial for both residential and commercial settings. Also, this pumping accessory helps to extend the life of the pumps.

  • They are designed for simple in-line installation.
  • Their inlet screen protects the bladder with minimal flow obstruction.
  • The units’ dual seal channels protect against air and system leaks.
  • Our range of pulsation dampeners are manufactured using the finest quality thermoplastics and elastomers.
  • They are constructed without wetted metal parts.
  • They work with minimum air consumption.
  • They are easy to install as their short, compact design requires no external bracing or other support structures.

How to Choose the Right Pulsation Dampener?

When selecting the right pulsation dampener, consider these key factors.

  • Ensure the dampener's capacity matches your system's flow rate and maximum pressure for effective performance.
  • Choose materials for the body, diaphragm, and other components that can resist the specific fluids in your application.
  • Assess the purpose, such as reducing noise or maintaining dosing accuracy, to determine the dampener's size and type.
  • Consider environmental factors like temperature and pressure fluctuations.
  • Opt for a design that is easy to maintain and service in your system setup.

Applications of Pulsation Dampeners

Our inline pulsation dampeners are majorly used with compressors and pumps to improve their performance and life. They are an important pump component responsible for the smooth flow of liquid through the pumps. The accessory immensely helps to absorb the vibrations and shocks created by the pump, which can otherwise cause damage to the system and affect the quality of the liquid being pumped. A few of the application areas of these units are:

  • Chemical
  • Petrochemical
  • Water treatment
  • Agriculture
  • Food Processing

Look no further than our company if you are looking for the best pulsation dampeners. We have a wide selection of dampeners to choose from, and we are confident that we can find the perfect one for your needs. We understand the importance of quality pulsation dampeners, and we guarantee that our products will meet your expectations. Our dampeners are made with the highest quality materials and are built to last.

Got Questions? We Have the Answers!

  • Can a pulsation dampener handle multiple fluids in the same system?

Yes, but it requires a diaphragm material compatible with all fluids to avoid degradation and ensure optimal performance.

  • Is a pulsation dampener suitable for both high- and low-pressure applications?

Yes, but dampener size, pressure rating, and diaphragm material must align with the application's pressure requirements for correct functioning.

  • What is the impact of gas type and pressure on the dampener?

Typically, nitrogen is used, and its pressure level is critical for dampening efficiency. Incorrect gas pressure can reduce dampener effectiveness.

  • How do pulsation dampeners affect dosing pump accuracy?

By minimizing flow fluctuations, dampeners stabilize discharge flow, enhancing dosing accuracy and reducing calibration frequency.