Description:
Simplified installation and low maintenance requirements help reduce operating costs. XL features simple volumetric programming, copy and clone functions, easy calibration, Automatic Formula Selection (AFS) and dose verification.
L5000 XL has 6 dosing modes:
- Smart Relay, Formula, Sequence, Latched and TAFS.
- Automatic Formula Selection (AFS) is available in Latched mode.
- In Continuous Batch Washer applications, all 8 pumps can run simultaneously.
Features
- Reduces installation and training time
- Reduces maintenance
- Fewer trouble calls
- PC-software compatibility
- Simplifies formula reconfiguration when replacing other dispensers
- Formula Selector/Programmer features 16-character alphanumeric LCD display
- Supports English, Portuguese, French-Canadian, Finnish, Turkish, French, Japanese, German, and Spanish.
Specification:
SIZE
Pump Box
Height: 9.4 in/23.88 cm
Width: 22.4 in/56.90 cm
Depth: 6 in/15.24 cm
Weight: 32.5 lbs./ 14.74 kg
Trigger Board (TR8000)
Height: 12.7 in/10.2 cm
Width: 3.6 in/9.1 cm
MATERIAL
Polypropylene body and fittings
Enclosure Material
Stainless 304
FLUSH MANIFOLD (OPTIONAL)
Water Inlet
Barb fitting for 1/2” ID tube, 10-20 PSI (.68 -1.36 bar) supply, flow 1.9 liters (0.5 gallons) per minute, (flow interlock at 0.38 liters/0.1 gallons per minute)
Chemical Connections
8 barb fittings for 3/8” ID tube
Discharge fitting for 1/2” ID tube
PUMPS
Peristaltic, dual roller, self-priming and self-checking
Nominal Flowrate
600 Series: 600 ml/min (20 oz/min) nominal
2000 Series: 2000 ml/min (68 oz/min) nominal
All pumps can run simultaneously. Pumps have a 10-minute continuous runtime limit.
Tube Connections
600 Series: Barb for 10 mm or 3/8”ID nylobraid, EVA, or equivalent
2000 Series: Barbs sold separately (1/2” for direct pumping to washer, 3/8” for connection to flush manifold)
Pump Box Mounting
Internal keyhole screw mounting, or optional rail mounting
RATINGS AND CONFORMANCE FOR ALL SYSTEM MODULES
CSA 22.2 No. 142, UL508, CE: EN61010, EN61326
TUV: GS (Pump box, not required on programmer because it is low voltage)
ELECTRICAL
Line Power (not CE):
90-260 VAC, 47-440 Hz, 100 watts (not CE)
Line Power (CE)
100-240 VAC 50/60 Hz (CE)
Component Connection
Plug-and-play telephone-style cable
Flush Valve Output
24 VDC, 0.5 Amp
Alarm Output
24 VDC 0.5 Amp and SPDT
24 VDC, 1 Amp Relay
Chemical Trigger Inputs
8 optically-isolated 24 - 120 VDC, 24 – 240 VAC, 20K ohm impedance*