Myron L

Myron L D-1 Dialysate Meter, Single Range

No reviews yet
SKU: Myron L D-1
Weight: 3.00 LBS
Shipping: Calculated at Checkout
$1,395.83
icon Share icon Share
  • product-security-image-1.jpg
  • product-security-image-2.jpg
  • product-security-image-3.jpg
  • product-security-image-4.jpg

Checkout securely with:

The choice of hemodialysis professionals for over 30 years, these compact instruments have been designed specifically to test dialysate solutions. By measuring electrical conductivity, they will quickly determine if dialysate concentrations are correct.

 

To use these hand-held instruments, the operator simply fills the cell cup with dialysate solution and pushes a button. The needle indicates the total concentrations of salts in the solution.

 

Model D-1 has an expanded scale of 11-15 millimhos and is useful for testing final dialysate. A unique feature of this model is the adjustable green color band above the dial. This provides an immediate visual confirmation of whether or not the dialysate concentration is within the patient?s ?safe zone?.

 

Model D-2 features dual scales on the dial and can test both acetate and bicarbonate dialysate. .

 

AUTOMATIC TEMPERATURE COMPENSATION: WHY IT?S IMPORTANT

The graph below illustrates conductivity readings of a 14.0 millimhos dialysate sample tested with a non-temperature compensated conductivity meter. The same sample APPEARS to have a higher level of dialysate concentration when heated (and lower concentration when chilled). Actually, only conductivity readings change with temperature. Dialysate concentration does not change. Some instruments ignore the importance of temperature. Others require a separate thermometer for testing sample temperature then manual adjustment of the meter. All Myron L instruments, however, feature fast and precise Automatic Temperature Compensation. The result: a more accurate, useful instrument.

Both instruments have built-in cell cups and are completely self-contained. They are powered by 9-volt batteries which last for at least 2,000 tests. A glow light serves as a battery reserve indicator.

 

Thousands of Myron L Dialysate Meters are still in daily use around the world after years of reliable service

 

FEATURES

Fast and accurate dialysate tests

Models for both acetate and bicarbonate solutions

Chip and crack resistant polyethylene cell cup

Rugged design

Simple to use

Automatic temperature compensation

 

D-1 Dialysis Meter

Customers Also Viewed