The On-Premise Pro is a three component system, with each component performing a specific function. See diagram below for illustration of the following:
- The Signal Interface Module (SIB) receives supply signals from the washmachine.
- Signals are routed to the Remote Control which controls all timing and programming functions. Pump run times and delay times are activated for the selected formula number.
- The output circuit board located inside the pump cabinet then runs the pumps for the correct amount of time.
FEATURES:
- 8 formula capability for various soil conditions
- Independent pump run times to provide specific volume injections
- Individual delay times for all wash formulas gives greater flexibility with fixed timer washwheels
- Programmed data is stored in non-volatile memory and not affected by voltage spikes or power outages
- Optional Drain Mode and Relay Mode
- Optional Auto Formula Select
- Formula and level enable/disable capability
- Flush mode can be used with all modes of operation
- Optional flush manifold with solenoid provides single line diluted chemical injection
- LED display on the remote control lets the user know which pump is running, and which formula is active
- The signal input circuitry will accept and verify a signal that is in the range of 24 to 240 volts