![Pyxis OxiPanel PLUS - IK-765SS-CLO-BP Auto-Brushing Chlorine Dioxide + pH Panel Pyxis OxiPanel PLUS - IK-765SS-CLO-BP Auto-Brushing Chlorine Dioxide + pH Panel](https://cdn11.bigcommerce.com/s-xxofluljba/images/stencil/448x448/products/69929/79053/OXIPANEL-PLUS-Oxidizer-pH-ORP-Anlayzer__97017__81348.1724240792.jpg?c=1)
![Pyxis OxiPanel PLUS - IK-765SS-CLO-BP Auto-Brushing Chlorine Dioxide + pH Panel Pyxis OxiPanel PLUS - IK-765SS-CLO-BP Auto-Brushing Chlorine Dioxide + pH Panel](https://cdn11.bigcommerce.com/s-xxofluljba/images/stencil/160w/products/69929/79055/OXIPANEL-PLUS-Auto-Brushing-Oxidizer-Analyzer-with-Flow-Control__69505__06957.1724240792.jpg?c=1)
Pyxis
Checkout securely with:
The OXIPANEL-PLUS IK-765-BP series are pre-mounted inline multi-parameter analyzers with integrated ultrasonic flow control. They are specifically designed as a ‘Turn-Key’ monitoring solution for challenging water applications. These include cooling water, food, industrial process water, raw water and treated waste water. This product offers highly accurate, repeatable, and real-time measurements of multiple oxidizer species. As well as pH, ORP and temperature utilizing proprietary Pyxis Lab smart sensor technology. Couple this with a Pyxis UC-80 color touch screen display and data logging terminal. As well as the Pyxis FS-100 ultrasonic flowmeter with regulating valve. The OXIPANEL-PLUS also incorporates the uniquely designed FR-300-PLUS automated mechanical brush flow assembly to maintain optimum sensor electrode cleanliness in the most challenging water where conventional membrane amperometric or wet chemistry analyzers would fail.
The OXIPANEL-PLUS IK-765-BP series are offered in four sensor formats depending on the desired oxidant being measured. The panel is designed with the propriety Pyxis ST-765SS Series smart sensor platform based on application needs. The ST-765SS Series sensors measure Free Chlorine (FCL), Total Chlorine (TCL), Bromine (Br) or Chlorine Dioxide (CLO). In addition to pH, ORP and temperature of the sample water. This Pyxis sensor design is membrane-free and based on unique principles incorporating Pyxis’ advanced technology of bare-gold electrochemical detection. All versions of the ST-765SS-Series sensor measure the oxidant level and pH simultaneously. Performing temperature and pH compensation for the measurement of oxidant based on conditions present in the application of use.
Each OxiPanel-PLUS panel comes with the FR-300-PLUS mechanical brushing flow assembly to ensure constant electrode cleanliness and the UC-80 color touch screen display and data logging terminal. This unique platform with internal sensor compensation results in a highly accurate oxidizer measurement consistent with DPD wet chemistry methodology as high as pH 9.0+ and meets EPA-334.0 and ISO-7393 compliance. The OXIPANEL-PLUS series also offers the FS-100 ultrasonic flow sensor and motor valve control module providing precise measurement and control of the incoming water sample flow based on user defined set point without the challenges commonly associated with mechanical flow measurement in dirty water applications.
Features
Specifications
Item | IK-765SS-Br-BP |
Part Number | 48076 |
Sensor Model | ST-765SS-Br |
Oxidizer Measured | Bromine |
Sensor | |
Sensor Body Material | 304 Stainless Steel |
Oxidizer Range | 0.00–5.00ppm |
Oxidizer Precision | ±0.01mg/L or 1%; pH Compensation up to 9.0 |
pH/ORP Range | 0.00–14.00 (±0.01 pH); -1,500 – +1,500mV (±1.0mV ORP) |
Measurement Interval | Continuous |
Sensor Response Time | T95≤60s - Oxidant / T96≤5s - pH |
Sensor Install Method | FR-300 Plus Magnetic Coupling Brush Flow Reservoir Assembly - INCLUDED |
Sensor Flow Interlock | Sensor Powers Down when in Auto-Mode if Flow <50mL/min and ON when >200mL/min |
Sample Op. Temp. | 4–49 ºC (40–120 ºF) |
Sample Inlet Pressure | 7.25–60psi (0.05–0.413MPa) |
Inlet/Outlet Line Size | 3/8in OD inserted into 1/2in FNPT Port |
FS-100 | |
Measurement Method | Ultrasonic Flow Detection |
Rated Flow Range | 0–3,000mL/min |
Resolution/Max Error | 1mL/min or ±2% of the value |
Display | 1.44” Color LCD 128x128 Resolution |
Flow Reg. Valve Control | 4–20mA from FS-100 (Internally Connected) |
FR-300 | |
FR-300 Flow Rate | 200–800mL/min (User uses FS-100 to set this parameter) |
FR-300 Flow Interlock | Brush Motor turns OFF when in Auto-Mode if Flow <50mL/min and ON when Flow >200mL/min |
FR-300 Rotation Speed | 200RPM, Motorized Brush |
UC-80 | |
Display | 4.3in LCD Color 480x272 Pixel Resolution / Resistive Touch |
Input | RS-485 Modbus - RTU |
Output | 3x 4–20mA / RS-485 Modbus RTU / Modbus-TCP |
Relay | 2x Relays (Passive Output or Active Output - User Selected) |
Data Storage | Built-In 128MB of RAM for Storing up to 1-Million Data/Event Records |
USB | 1x USB Host for Data Downloading and Screen Upgrade |
Relative Humidity | 20–90% (No Condensation) |
Altitude | <6,561 ft (<2,000m) |
PANEL | |
Panel Power Supply | 90–260VAC / 50–60 Hz; 60W USA Type B Plug |
Storage Temperature | -4–158 ºF (-20–70 ºC) |
Dimension | Panel 450H x 750W x 180D mm |
Approximate Weight | Panel ~ 10kg |
Panel Wet Material | Polycarbonate/304SS/316SS/Glass/Gold/Platinum/CPVC/PTFEPOM/ABS/PEEK/PET/NBR |
Rating | IP-65 Panel Display / IP-67 Sensors |
Compliance | EPA-334.0 / ISO-7393 |
Regulation | CE Marked / RoHS / UKCA |
Selectivity | Non-Selective, Cross Sensitive to Other Oxidizing Species |
Warranty | 6 Months Electrode / 13 Months Sensor Body and Panel |
Electrode Service Life | 2 Years |
Brush Life | 12–18 Months depending on Application |
Pyxis 4G LTE Gateway | Included & Activated On Request with Enrollment |