ST-711 | Inline ORP Sensor

Pyxis

$814.00
(No reviews yet) Write a Review
SKU:
53002
Weight:
0.37 LBS
Shipping:
Calculated at Checkout
Adding to cart… The item has been added

Description:

The ST-711 an inline single-channel ORP sensor that is specifically designed to simplify installation, calibration and operation in process, industrial, waste and cooling water applications. This sensor offers an embedded transmitter and can be utilized in both 4–20mA or RS-485 Modbus formats. When used in RS-485 format, the ST-711 also provides a temperature output signal. These features dramatically improve application possibilities allowing the ST-711 to be directly connected to most OEM controller, PLC or DCS systems.

The ST-711 has an oversized platinum disk for ORP that increases resistance to highly turbid waters and contamination. The enlarged salt bridge design with large junction capacity also ensures a long sensor life with minimal maintenance. This device is ideally suited for “hard-to-measure” waters where conventional ORP sensors would otherwise fail or require high maintenance costs. The ST-711 does NOT require electrode change-out or Potassium Chloride (KCl) re-fill, and is designed to be used until the end of life and then completely swapped out.

Typical Applications:

  • Industrial Process & Cooling Water
  • Fresh, Brackish, Sea Water
  • Raw, Influent Water
  • Wastewater Effluent
  • Surface & Storm Water

Features:

  • Dual Embedded Transmitter – 4–20mA and RS-485 supporting Modbus
  • Compact Design for Small Footprint, Ideally Suited for Industrial Applications
  • Tolerant to Frozen Conditions during Shipment or Storage
  • Large Junction Capacity (Compared to Replaceable Electrode Design) Leading to Longer Service Life and Less Maintenance
  • Stainless Solution Grounding Point on Sensor to Stay Away from Ground Loop Problems
  • Interfaces with Pyxis Lab® MA-WB Wireless Adapter or PowerPACK Auxiliary Box

Specifications:

ST-711 ORP Sensor
P/N 53002
ORP Range ±1,500 mV Range with ±1.0mV Precision
Response Time 95% within 5 Seconds
Power Supply 12–36VDC, ~1W
Output 4–20mA Isolated, RS-485 Isolated
Connector IP67 Water-Proof Connector/Cable 1.5m (4.5ft)
Operation Pressure Up to 0.7MPa (100psi)
Installation ST-001 Pyxis Lab® Standard 3/4inch NPT Tee for Panel Mount or Pipe Clamp
MA-102S Submersion Adapter for Submersed Applications
Storage Temperature -20–60 ºC (-4–140 ºF)
Operational Temperature 40–120 ºF (4–49 ºC)
Housing Material CPVC
Dimension 6.8inch (172.7mm) L, 1.44inch (36.6mm) D
Weight 0.37lbs (170g)
Typical Service Life 2+ Years
Warranty 13 Months from Date of Shipment
Regulation CE / RoHS