SONIC-PRO® Chemical Feed Flow Meter
The MS6 accurately measures liquid chemical feed from ranges of 10 – 5,000 mL/min and 100 – 10,000 mL/min.  This plug-and-play flow meter works right out of the box but is easily configurable via Blue-Central® desktop software.
Pre-calibrated chemicals include Water, Aqueous Ammonia 10%, Ammonium Hydroxide 30%, Ferric Chloride 40%, Sodium Hypochlorite 12.5%, Sodium Permanganate 40%, Hydrofluorosilicic Acid 25%, and Ammonium Sulfate 10%.  Additional chemicals can be calibrated by performing a custom chemical calibration.
Technical Overview:
- mL/min: 10 - 10000
 
- GPH: .158 - 158.5
 
- PSI: 200
 
- Bar: 13.78
 
- Fahrenheit (°F): 104
 
- Celsius (°C): 40
 
- Body Material: PVDF, PEEK
 
- Pipe Sizes: ½” barb, ½” M/NPT, ½” PVC slip
 
Features
Benefits:
- Flow Range 1: 10 – 5,000 mL/min (0.158 – 79.2 GPH)
 
- Flow Range 2: 100 – 10,000 mL/min (1.58 – 158.5 GPH)
 
- Sensor is NSF 61 Listed
 
- Inline pipe fittings for easy installation
 
- Configurable via Blue-Central® desktop software
 
- Isolated 4-20 mA output – fully configurable
 
- 0-10000Hz Pulse output – fully configurable
 
- User configurable flow rate and total set-point triggers
 
- Flow-rate readings as low as 10 mL/min
 
- Included wetted end fittings allow for more than 14 inlet and outlet configurations
 
- True unions for ease of maintenance
 
- Wetted components constructed out of PVDF and PEEK
 
- Quick visual inspection with built in status LED light
 
- Process control via configurable solid state relay, which can be configured to close or open trigger at a flow-rate or to flow total for batching operation
 
Specifications
Electronics/Hardware
SPU (Signal Processing Unit):
Enclosure
- NEMA 4X (IP66) Polycarbonate, SS hardware.
 
- Dimensions: 10.02H x Ø3.79 inches (254.5H x Ø96.1 mm)
 
- Weight 1.5 lb. (.68 Kg.)
 
Power Requirements
Environmental Conditions
- Operating temp: 14 F to 104 F (-10 C to 40 C)
 
- Storage: -40 F to 158 F (-40 C to 70 C)
 
- Relative humidity: 0% – 90%
 
Display
- Type: Liquid Crystal Display
 
- Backlight: White LED backlight
 
Software Language
Volume Units
- Independently configurable Rate and Total units in: U.S. Gallons, Liters, or Milliliters.
 
Time Units
- Seconds, minutes, hours, days.
 
Flow Rate Averaging
- Selectable: 1, 4, 8, 16, and 32 seconds.
 
Data Outputs
- Isolated 4-20 mA output – fully configurable
 
- 0-10000 Hz Pulse output – fully configurable
 
Process Control
- One Solid State Relay
 
- Load capacity: 24VDC, 100mA max (ex. supplied)
 
- Configure to flow rate for high/low/range rate trigger. Programmable release values enable auto release or manual latching operation.
 
- Configure to flow total for automatically triggered, timed batch operations for proportional feed applications.
 
Power Supply (user configurable)
- Includes each of the following:
 
- U.S. Transformer, 115VAC 60HZ / 5VDC, NEMA 5/15 plug
 
- Europe Transformer, 230VAC 50HZ / 5VDC, CEE 7/V11 plug
 
- Australia / New Zealand Transformer, 240VAC 50HZ / 5VDC, AS 3112 plug
 
- U.K. Transformer, 230VAC 50Z / 5VDC, BS 1363/A plug
 
Blue-Central® Software
Software Features
- Configurable 4-20mA, Pulse Output, Frequency Output
 
- Solid State Relay Set-Point
 
- Monitor flow rate in real time
 
- Monitor total volume in real time
 
- Monitor meter diagnostics
 
- Field Upgradable Firmware
 
- Factory Resettable
 
- TDS #85000-137 rev.17 20191203
 
Compatible Operating Systems
- Windows 7, 8, and 10
 
- Mac (OSX 10.11/10.12/10.13)
 
Computer Connector
- USB-C (USB-A to USB-C cable included)
 
Wetted Materials
Transducer
Body
O-Rings
Fittings (Included)
- PVDF 1/2” I.D. Barb
 
- PVDF 1/2” I.D. Barb Elbow
 
- PVDF 1/2” M/NPT
 
- PVDF 1/2” M/NPT Elbow
 
- PVC 1/2” Slip
 
General Operation
Pre-Calibrated Chemical Profiles
- Water
 
- Aqueous Ammonia
 
- Ammonium Hydroxide
 
- Ferric Chloride 40%
 
- Sodium Bisulfite 40%
 
- Sodium Hypochlorite 12.5%
 
- Sodium Permanganate
 
- Hydrofluorosilicic Acid 25%
 
- Ammonium Sulfate 10%
 
Compatible Fluid Types
- Acoustically conductive fluids
 
- Particulate and bubbles with 50,000 ppm or less