BW103 All-In-One Steam Boiler Treatment

Oxygen Scavenger - Deposit Control - Alkalinity Control - Steam Line Protection

 Product Description

  • Concentrated: 14 - 21 ounces treats 1000 gallons of feed water.
  • Balanced blend of alkalinity boosters, sulfite oxygen scavengers and polymeric organic dispersants.
  • Has a dedicated iron oxide dispersants to retard rust deposits.
  • Contains a steam line treatment that neutralizes low acidic pH in the condensate return lines.
  • Can be used on steam boilers that have hard water makeup, however, for best results soften makeup water.
  • Ingredients in BW103 meet FDA/USDA guidelines for use in treating boilers where the steam produced may contact edible food products.
  • BW103 is intended for use in boilers operating in the low and medium pressure range below 300 psi.

 BW103 Application Rate and Control Parameters

  • BW103 should be fed with a chemical metering pump into the feed water storage tank or feed water line.  If possible, interlock the chemical metering pump to the boiler feed water pump so that chemical is fed in proportion to load.
  • Use Sulfite Test Kit P.N.# CNTK3502-Z to test for BW103.  The recommended test range is 30 - 60 ppm as Sulfite.
  • Log test results.  Read Cannon Water Technology Inc.’s “Basic Steam Boiler Water Treatment”.

 Physical Properties: BW103

Form:

Liquid

Color:

Light Amber

Odor:

Amine, Ammonia

pH:

12+/-

Density:

9.82#/gallon

Specific Gravity:

1.17

Freeze Point:

Approximately 32° F

Freeze/Thaw Recovery:

Partial

Ship Class:

Corrosive Liquid, N.O.S.

UN1760

 

 

Contains:

Sodium Hydroxide, Cyclohexylamine, and Morpholine PG II

 

 

 HMIS Code

301J

 

 

Refer to the BW103 SDS for further health, safety and environmental information regarding this product. Information and recommendations in this bulletin are based on information believed to be reliable. However, the use of the product is beyond the control of Cannon Water Technology Inc. and no guarantee, expressed or implied, is made as to the effects of such the results to be obtained if not used in accordance with directions or established safe practice. The buyer must assume all responsibility, including injury or damage, resulting from misuse of the product as such, or in combination with other material.

 

All-In-One Steam Boiler Treatment with a steam line treatment for steam lines greater than 1000 feet and steam losses greater than 10%. Dosage: 14 - 21 ounces per 1000 gallons of feed water.