EchoPod DL34 Ultrasonic Level Sensor with 4 relays, 4-20 mA out, Up to 18' Range

Flowline

$741.26 - $801.16
(No reviews yet) Write a Review
SKU:
DL34
Weight:
3.00 LBS
Shipping:
Calculated at Checkout
Adding to cart… The item has been added

Description

EchoPod DL34, the general purpose, ultrasonic sensor provides non-contact level detection up to 18' (5.5 m) with 4 SPST 60 VA 1A relays and a two-wire 4-20 mA level measurement output. Each relay can be configured on a single set point alarm or latched on two sets for automatic fill or empty in simplex or duplex control modes with fail-safe logic. The embedded controller can replace external control hardware. The sensor is well suited for a wide range of corrosive, sticky or dirty type media. EchoPod is broadly selected for day tanks, sumps, IBC totes, lift stations and mini-bulk storage applications. To configure EchoPod, download Flowline's free WebCal software and purchase one USB interface tool.

Advantages

  • Multi-function sensor provides 4-20 mA measurement, switch and control functions.
  • Compact sensor with 3" beam width and 8" dead band optimized for medium to large sized tank applications.
  • Four 1A relays programmable for switch or advanced pump or valve control and fail-safety.
  • Rugged PVDF transducer and polycarbonate enclosure rated 6P for corrosive applications.
  • WebCal, an innovative PC user interface that provides fast and accurate configuration
  • Control/switch point functions include:
    • 2 pumps with 2 alarms
    • 1 pump with 3 alarms
    • 2 pumps (dead-lag) with 2 alarms
    • 2 pumps (duplexing) with 2 alarms
    • 4 independent switch point alarms
EchoPod® is user configured via our WebCal® software through the Fob USB interface tool P/N LI99-1001

Technical Specifications

Range

 18' (5.5m)

Accuracy:

± 0.2% range

Resolution:

0.019" (0.5mm)

Beam Width:

3" (7.62 cm)

Dead band:

8" (20 cm)

Supply voltage:

24 VDC (loop)

Loop resistance:

400ΩO max

Consumption:

0.5W

Signal output:

4-20mA, two-wire (when loop powered)

Contact type:

(4) SPST relays 1A

Loop fail-safety:

4 mA, 20 mA, 21 mA, 22 mA or hold last

Relay fail-safety:

Power loss: Hold last
Power on: Open, close or hold last

Hysteresis:

Selectable

Configuration:

WebCal® (PC Windows®)
USB 2.0

Temp. comp.:

Automatic over range

Process temp.:

F: -20° to 140°
C: -7° to 60°

Pressure:

MWP = 30 PSI 2 BAR

Enclosure:

Type 6P, encapsulated, corrosion resistant & submersible

Encl. material:

PC

Strain relief mat.:

Santoprene

Trans. material:

PVDF

Cable length:

48" (1.2m)

Cable jacket mat.:

Polyurethane

Process mount:

2" NPT (2" G)

Mount. gasket:

Viton®

Classification:

General purpose

Approval:

cFMus, CE

Compliance:

RoHS

EchoPod DL34 has 4 built in relays and 4-20 mA signal output. Measures up to 18'