Myron L

Myronl L UltrapenX2 PTBT5 Dissolved Oxygen (DO) and Temperature, Bluetooth Enabled

No reviews yet Write a Review
SKU: PTBT5
Weight: 1.00 LBS
Shipping: Calculated at Checkout
$662.00
icon Share icon Share
  • product-security-image-1.jpg
  • product-security-image-2.jpg
  • product-security-image-3.jpg
  • product-security-image-4.jpg

For use with PTBTX2 App on your mobile device

ULTRAPENx2™ PTBT5 Benefits:

  • Reliable Repeatable Results
  • Accurate
  • Affordable
  • Easy to Use
  • Rugged Design
  • Ensure Product Quality
  • Reduce Waste
  • Protect the Environment

 

ULTRAPENx2™ PTBT5 High Performance Features:

  • Industry Leading Accuracy
  • Display DO in Concentration, % Saturation, or Both
  • Adjustable for Altitude and Salinity
  • 3 Calibration Methods: Air, Water and 0 ppm DO
  • Dynamic Membrane Temperature Correction
  • Measurement Storage with Time, Date and Location
  • Export Stored Measurement Data Via Email
  • Live or Hold Mode – User Selectable
  • Proprietary Sensor Design
  • Rugged Design with Aircraft Aluminum Body
  • Durable, Epoxy Encapsulated Electronics
  • Waterproof
  • Powered by One N Type Battery (Included)

 

ULTRAPENx2™ PTBT5 Comes With:

  • PTBT5 Pocket Tester Pen
    • Battery Installed
  • User Replaceable DO Sensor
    • Installed
  • Membrane Cap Assemblies
    • 3 each
  • DO Reference Electrolyte Solution – 2 oz.
  • Syringe with Tip
  • Protective/Hydration Cap
  • Pocket Clip
  • Quick Start Guide

 

ULTRAPENx2™ PTBT5 Specifications:

System Requirements: Myron L® Company PTBTX2TM App: Apple iOS 10.0 or later; Android OS 7.0 or later.

 

Specifications DO Concentration DO Saturation Temperature
Ranges 0-20 ppm 0-200% 0 – 71°C / 32 – 160°F
Accuracy1 ± 0.2 ppm or ± 2% of the reading, whichever is greater (up to 40ºC) 0.0% to ≤ 100.0%: ± 20 counts; >100%: ± 2% of the reading. ± 0.1°C
Resolution 0.01 ppm 0.1% 0.1°C/F

 

Altitude Adjustment: -2,000 ft. to 15,000 ft. in increments of 100 ft.
Salinity Adjustment: 0 – 50 ppt in increments of 1 ppt
Time to Reading Stabilization: 10 – 180 seconds
Calibration Methods: 1 or 2 Point; 0 ppm DO Calibration Solution, Air or Water
Operating/Storage Temperature: 0 – 55°C / 32 – 131°F
Power Consumption: Active Mode: 30 – 140 mA, Sleep Mode: 2 µA
Temperature Compensation for Membrane Permeability: Automatic
Physical Dimensions: 17.15 cm L x 1.59 cm D or 6.75 in. L x .625 in. D
Weight: 54 g or 1.94 oz.
Case Material: Anodized Aircraft Aluminum with Protective Coating
Battery Type: N type, Alkaline 1.5 V
Water Resistance: IP67 and NEMA 6
EN61236-1: 2006 – Annex A: 2008; 1999/5/EC Annex III Electrostatic discharge to case of instrument may cause PT5 to spontaneously power ON. In this case, the PT5 will power OFF after several seconds.  
  WARNING! These products can expose you to chemicals including Di(2-ethylhexyl)phthalate (DEHP), which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

1Accuracy after Temperature Controlled, Full Calibration.

 

ULTRAPENx2™ PTBT5 Measurement Modes:

MODE METHOD OF MEASUREMENT
Hold Displays real-time readings until stable or 3 minutes, whichever comes first, then displays final readings.
LIVE Displays real-time readings continuously for up to 5 minutes.

 

ULTRAPENx2™ PTBT5 Parameter Modes:

MODE PARAMETER MEASURED
DO Default Display alternates between DO Concentration in ppm, DO Saturation in % and Temperature.
DO Concentration Display alternates between DO Concentration in ppm and Temperature.
DO Saturation Display alternates between DO Saturation in % and Temperature.

Customers Also Viewed