Myron L
Myron L
Myronl L UltrapenX2 PTBT5 Dissolved Oxygen (DO) and Temperature, Bluetooth Enabled
SKU:
PTBT5
Weight:
1.00 LBS
Shipping:
Calculated at Checkout
HK$5,670.23
For use with PTBTX2 App on your mobile device
ULTRAPENx2™ PTBT5 Benefits:
- Reliable Repeatable Results
- Accurate
- Affordable
- Easy to Use
- Rugged Design
- Ensure Product Quality
- Reduce Waste
- Protect the Environment
ULTRAPENx2™ PTBT5 High Performance Features:
- Industry Leading Accuracy
- Display DO in Concentration, % Saturation, or Both
- Adjustable for Altitude and Salinity
- 3 Calibration Methods: Air, Water and 0 ppm DO
- Dynamic Membrane Temperature Correction
- Measurement Storage with Time, Date and Location
- Export Stored Measurement Data Via Email
- Live or Hold Mode – User Selectable
- Proprietary Sensor Design
- Rugged Design with Aircraft Aluminum Body
- Durable, Epoxy Encapsulated Electronics
- Waterproof
- Powered by One N Type Battery (Included)
ULTRAPENx2™ PTBT5 Comes With:
- PTBT5 Pocket Tester Pen
- Battery Installed
- User Replaceable DO Sensor
- Installed
- Membrane Cap Assemblies
- 3 each
- DO Reference Electrolyte Solution – 2 oz.
- Syringe with Tip
- Protective/Hydration Cap
- Pocket Clip
- Quick Start Guide
ULTRAPENx2™ PTBT5 Specifications:
System Requirements: | Myron L® Company PTBTX2TM App: Apple iOS 10.0 or later; Android OS 7.0 or later. |
Specifications | DO Concentration | DO Saturation | Temperature |
Ranges | 0-20 ppm | 0-200% | 0 – 71°C / 32 – 160°F |
Accuracy1 | ± 0.2 ppm or ± 2% of the reading, whichever is greater (up to 40ºC) | 0.0% to ≤ 100.0%: ± 20 counts; >100%: ± 2% of the reading. | ± 0.1°C |
Resolution | 0.01 ppm | 0.1% | 0.1°C/F |
Altitude Adjustment: | -2,000 ft. to 15,000 ft. in increments of 100 ft. |
Salinity Adjustment: | 0 – 50 ppt in increments of 1 ppt |
Time to Reading Stabilization: | 10 – 180 seconds |
Calibration Methods: | 1 or 2 Point; 0 ppm DO Calibration Solution, Air or Water |
Operating/Storage Temperature: | 0 – 55°C / 32 – 131°F |
Power Consumption: | Active Mode: 30 – 140 mA, Sleep Mode: 2 µA |
Temperature Compensation for Membrane Permeability: | Automatic |
Physical Dimensions: | 17.15 cm L x 1.59 cm D or 6.75 in. L x .625 in. D |
Weight: | 54 g or 1.94 oz. |
Case Material: | Anodized Aircraft Aluminum with Protective Coating |
Battery Type: | N type, Alkaline 1.5 V |
Water Resistance: | IP67 and NEMA 6 |
EN61236-1: 2006 – Annex A: 2008; 1999/5/EC Annex III Electrostatic discharge to case of instrument may cause PT5 to spontaneously power ON. In this case, the PT5 will power OFF after several seconds. | |
WARNING! These products can expose you to chemicals including Di(2-ethylhexyl)phthalate (DEHP), which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov. |
1Accuracy after Temperature Controlled, Full Calibration.
ULTRAPENx2™ PTBT5 Measurement Modes:
MODE | METHOD OF MEASUREMENT |
Hold | Displays real-time readings until stable or 3 minutes, whichever comes first, then displays final readings. |
LIVE | Displays real-time readings continuously for up to 5 minutes. |
ULTRAPENx2™ PTBT5 Parameter Modes:
MODE | PARAMETER MEASURED |
DO Default | Display alternates between DO Concentration in ppm, DO Saturation in % and Temperature. |
DO Concentration | Display alternates between DO Concentration in ppm and Temperature. |
DO Saturation | Display alternates between DO Saturation in % and Temperature. |