ORP Meters

Access to clean water is a basic necessity, whether it is for drinking, domestic use, swimming pools, or any other reason. While there are filtration and purification units set at government and private levels to filter the contaminants in water. However, for effective filtration can be done only if its oxidation reduction potential (ORP) is  known. This ORP can be checked using ORP meters. Cannon Water provides some of the best ORP water meters of known brands such as Myron LHM Digital, and so on. These ORP meters are used for water testing in commercial, residential, and industrial applications. These are handy devices, easy to carry anywhere you go. Browse our collection to see the best ORP measurement device for your needs.

Sidebar Sidebar Sidebar

Types of ORP Meters Offered by Cannon Water

Oxidation and reduction properties of water help highlight its level of contamination, pH, effectiveness of purifying agents, and other sanitation factors. Ideally, water must be an oxidizing agent as it will seek to get a number of electrons from the purifier substance, such as chlorine, mixed in it. An oxidizing agent would get a positive reading on an ORP meter. On the other hand, if it tests negative for water, one may have to change the water treatment plan. Here are the types of ORP meters for drinking water and other purposes we offer:

  • Waterproof ORP Meter: This compact and extremely lightweight ORP meter weighs just 0.50 pounds. This ORP analyzer offers oxidation and reduction level and temperature readings. It is factory-calibrated up to +200 mV and can be recalibrated.
  • ORP pH Meter: This extremely compact palm sized meter offers an amazing level of accuracy for pH and ORP readings. Aside from these two factors, it shows the temperature and date over a good digital display.
  • ORP Ultrameter for Pool: This ORP water quality pocket meter is ideal for testing the water in swimming pools and spas. It is designed to check water balance, disinfectant residue, chlorine, salinity, TDS, and so on.
  • ORP PS9-BD Ultrameter: This digital all-in-one meter is calibrated to offer various readings such as pH, hardness of water, mineral content, alkalinity, ORP for chlorine, salinity, and so on. This handy instrument weighs around 200 pounds.

Most ORP meters displayed here are offered with accessories such as pH buffer solutions, wires, batteries, and so on. We also offer ORP water meter kits with all these accessories which come in a protective carry case.

Key Features of ORP Meter for Water Measurement Offered by Cannon Water Technology

A few of the notable features of our range of ORP meter for water include;

  • Our range of ORP water testers are specifically manufactured for long-term use and are built to withstand challenging conditions.
  • These ORP analyzer meters come with a large, easy-to-read LCD screen that displays all the measurements in real-time.
  • The ORP measurement meters’ data-logging function allows you to store several measurements.
  • These meters are small and lightweight, making them easy to transport.
  • They are light weight and waterproof (housing is IP-67 rated)- perfect for testing the quality of water in any environment.
  • These meters are equipped with a replaceable ORP electrode, which is ideal for environmental and industrial applications involving monitoring water quality.
  • They provide simultaneous temperature readings, allowing instantaneous results for more accurate monitoring.
  • The meters are designed with auto-off function, data-hold function and low-battery indicator.

Significance of Measuring Oxidation-reduction Potential (ORP) Across Industries

It is essential to measure ORP across a range of industries due to its ability to assess an oxidative or reductive state of a system. ORP refers to the electron activity in the solution, indicating whether it can accept or donate electrons. This measurement is performed using ORP testers. Here's a breakdown of the importance of ORP measurement in various industries:

  • Mining and Metallurgy: ORP plays a crucial role in various hydrometallurgy processes, such as leaching, where metals are extracted from ores through chemical reactions. Monitoring ORP ensures optimal conditions for extracting specific metals, such as gold or copper, by maintaining the right redox balance.
  • Water Treatment Industry: ORP is crucial for disinfection in water systems. Values above 650 mV in drinking water indicate effective pathogen control and proper disinfectant function. In wastewater treatment, ORP optimizes biological processes for efficient waste breakdown. Maintaining ORP water tester levels of 650-750 mV for pools and spas ensures effective disinfection and prevents over-chlorination.
  • Food and Beverage Industry: ORP plays a vital role in food processing by controlling oxidation and reduction reactions, which is particularly important in wine and juice production to prevent spoilage and undesirable flavors. In the beverage industry, ORP is measured to ensure water quality and microbial safety. Proper ORP levels enhance food preservation by minimizing oxidation. These are crucial in pasteurization processes where disinfection is essential.
  • Pulp and Paper Industry: In pulp and paper industry, ORP is especially measured during bleaching processes. These processes involve oxidizing agents like chlorine or hydrogen peroxide. Controlling ORP ensures effective bleaching while minimizing environmental impact.
  • Aquaculture and Fisheries: ORP maintains the water quality in fish farms or aquariums. Proper ORP levels ensure a healthy environment for fish by preventing harmful bacterial growth and optimizing oxygen levels, which are critical for aquatic life.
  • Pharmaceutical and Biotechnology: During fermentation and biochemical processes, ORP manages the oxidative state of the media. This ensures the viability of microorganisms essential for antibiotic production and other biotechnological applications. Additionally, ORP is tracked in drug stability testing to maintain potency and prevent oxidative degradation.
  • Chemical and Petrochemical Industry: Like other industries, ORP plays a crucial role in the chemical and petrochemical industry. Electroplating is used to maintain the necessary oxidative or reductive environment for consistent metal deposition. In corrosion control, it monitors the oxidizing potential of a medium, helping assess corrosion risk and the effectiveness of corrosion inhibitors.

Factors to Consider When Choosing an ORP Meter

Several factors should be considered while selecting ORP meters for your applications. Here are some important ones that will help you make informed decisions:

  • Accuracy and Range: These are essential aspects of selecting ORP water meters. Most sensitive segments, including water treatments and food processing, demand high-precision, ranging from ±1 to ±5 millivolts. Depending on the application’s specific needs, the ORP tester should also cover a suitable measurement range, such as -2000 mV to +2000 mV.
  • Material Compatibility: This is another critical factor to consider. Ensure the electrodes are made from high-quality materials resistant to environmental conditions. The electrode type also matters, with combination and interchangeable electrodes providing flexibility and ease of maintenance.
  • Automatic Temperature Compensation (ATC): This is vital for accurate ORP readings, especially in fluctuating temperatures. Meters with ATC and integrated temperature sensors enhance precision.
  • Calibration and Maintenance: Periodic calibration and maintenance are essential to keep ORP meters working as expected. Choose meters that offer easy calibration with standard buffer solutions and require minimal upkeep.
  • Data logging and Connectivity: This feature allows for trend monitoring and compliance reporting. ORP water meters with USB or wireless connectivity facilitate data management, crucial for detailed process control.
  • Features and Costs: While initial investment of ORP water tester varies widely, consider long-term costs associated with consumables, such as replacement electrodes and calibration solutions.
  • Compliance and Standards: It's essential to consider regulatory requirements, as different industries may necessitate compliance with specific standards. For instance, food and pharmaceutical sectors often require FDA compliance, while drinking water applications must adhere to NSF/ANSI standards. Additionally, certifications are crucial in pharmaceuticals and food production industries, where meters should meet sanitary standards and comply with ISO or Good Manufacturing Practices (GMP) to ensure safety and quality.

ORP Meters Maintenance Tips

Maintaining an ORP meter ensures accurate and reliable readings over time. Proper maintenance extends the life of the meters, provides consistent results, and prevents costly downtime. Here are vital tips to keep ORP meters in optimal condition:

  • Regular Calibration: Calibration is essential for accurate ORP readings, as electrodes can drift over time. Follow the manufacturer's guidelines using fresh buffer solutions and always rinse the electrode beforehand to prevent contamination.
  • Cleaning the Electrode: Regular cleaning prevents dirt and chemical buildup on the electrode, ensuring accurate readings. Soak in a mild solution and gently brush to remove deposits, avoiding abrasive materials that could damage the electrode.
  • Proper Storage: Store ORP meters in recommended solutions to prevent electrode dehydration. Avoid storing them dry or in distilled water, which can damage the electrode over time. Use storage solutions for prolonged storage.
  • Avoid Physical Damage: Handle ORP meters carefully to prevent damage from drops or extreme conditions. Use protective caps and cases during transport to safeguard against accidental harm.
  • Check for Response Time: Monitor the electrode's response time when taking readings. A slow response may indicate contamination or wear, requiring cleaning or calibration; persistent issues might necessitate electrode replacement.
  • Replace Worn Electrodes: Electrodes degrade with use, especially in harsh conditions. Regularly inspect and replace them if calibration fails or readings become erratic. Keep spare electrodes for critical monitoring applications.
  • Monitor and Control Temperature: Temperature fluctuations can affect ORP readings. Use ORP testers with automatic temperature compensation or measure temperature separately and adjust readings accordingly, protecting the meter from extremes.
  • Use Compatible Solutions: Always use manufacturer-recommended cleaning, storage, and calibration solutions to avoid electrode damage. Non-compatible solutions can affect accuracy, especially in specific applications like chlorine monitoring.

FAQ’s on ORP Testers

Here are some frequently asked questions about ORP testers, along with their answers.

1.      Why is ORP important?

ORP (Oxidation-Reduction Potential) is essential for testing the quality of water because it allows determine the sanitation and contamination of water in a given sample is. This important parameter is determined by measuring the oxidation and reduction properties in a given sample.

2.      How do I use an ORP tester?

ORP reading can be tested accurately using an ORP Probe, which consists of two electrodes - an ORP Electrode and a Reference Electrode. To use the probe, simply dip it into the solution you wish to test and the ORP reading will display on the tester's panel. With this device, measuring ORP levels is effortless.

3.      How often should I calibrate my ORP meter?

ORP meter calibration is essential for precise readings. To ensure reliable measurements, you should aim to calibrate your ORP meter at least once a month. Depending on how frequently you use your ORP meter, it may be necessary to perform calibration more often than that.

4.      If an ORP reading is drifting, do you doubt the capability of the meter?
If an ORP reading is drifting, it could be due to a variety of factors, including the sensor, the solution being measured, or the instrument itself. Further troubleshooting may be necessary to determine the cause.

5.      What factors can impact ORP readings?

Factors that can impact ORP readings include pH level, temperature, and the presence of other dissolved species in the water.

6.       How should I maintain ORP water quality tester?

The following are the tips to maintain ORP tester.

  • Keep the tester clean. Wipe it down with a soft, clean cloth after each use.
  • Store the tester in a cool, dry place.
  • If the tester is not being used for an extended period of time, remove the batteries.
  • Make sure to cover it with a clean, dry cloth if the unit is not in use. This will protect the sensor from dust and debris.