Pyxis
Pyxis
Pyxis HM-500 Oil In Water Sensor (0-10ppm)
Checkout securely with:
The Pyxis Lab® HM-500 series of inline fluorometer sensors measure the concentration of oil in water, read as ppm Marine Crude-Offshore Oil. The sensors utilize an LED sourced UV-fluorescence methodology at 365nm wavelength & 410/470nm excitation. Our HM-500 series of sensors are uniquely designed with extra photo-electric components that also monitor the color & turbidity of the sample water. This proprietary feature enables the HM-500 series to automatically compensate for color and turbidity in the water sample eliminating interferences commonly associated with real-world waters, up to 150NTU. These sensors have a short fluidic channel and can be easily cleaned.
The fluidic & optical arrangement of the HM-500 series are designed to overcome short comings associated with other fluorometers that have a distal sensor surface or a long, narrow fluidic cell. Traditional inline fluorometers are susceptible to color/turbidity interference & fouling and can also be very difficult to clean. These unique features provide the HM-500 series with a level of accuracy far greater than conventional inline oil in water sensors & enable users to conduct wireless inline sensor cleanliness diagnostics as a predictive measure via the uPyxis® for mobile and desktop devices.
Features
- PROVIDED with the ST-001 Inline Tee Assembly 3/4inch FNPT/CPVC
- Offers a 304 Stainless Steel 3/4inch FNPT variant for Harsh Applications
- Submersion Adapter Kit (MA-102S) Available for CPVC Submersed Applications
- Unique Design with Extra Photo-Electric Components
- Automatically Compensates for Color & Turbidity Contamination
- Flexible/Advanced Communication 4-20mA Output & RS-485 Output
- Connectible to ANY Conventional Microprocessor Controller, PLC or DCS
- Bluetooth® Enabled when used with the MA-WB or PowerPACK Series of Adapters
- Bluetooth® Wireless Interface via uPyxis® app
- uPyxis® allows for Sensor Cleanliness Diagnostics, Calibration & Configuration
- uPyxis® allows users to Write Calibration to Sensors for a Variety of Oils as ppm
- Lower Cost & Higher Accuracy vs Conventional UV Fluorometers for Oil in Water
Typical Applications
- Heat Exchanger Leak Detection
- Oil Tank Leakage Detection
- Intake Water Monitoring (UF & RO Feedwater)
- Reinjection Water Monitoring
- Industrial Wastewater Monitoring
- Marine Discharge Monitoring
- Plant Runoff / Storm Water Monitoring
Specifications
ST-500 Inline PTSA Sensor | |
---|---|
P/N | 50661 |
PTSA Output Scale Adjusted via uPyxis® | 0–200ppb |
PTSA Maximum Range Adjusted via uPyxis® | 0–300ppb |
PTSA Precision/Accuracy | ±1ppb |
Excitation/Emission | LED 365/410nm |
Power Supply | 22–26VDC, Power Consumption – 1W |
Outputs | Isolated 4–20mA Analog Outputs & Isolated RS-485 Digital Output – 7Pin |
Installation | ST-001 Inline Tee (Provided) 3/4″ FNPT Socket & Thread |
Weight | 170g (0.37lbs) |
Operational Pressure | 100psi (6.9 Bar) |
Operating Temperature | 4–49 ºC (40–120 ºF) |
Storage Temperature | -20–60 ºC (-4–140ºF) |
Material | CPVC |
Rating | IP67, Fully Dust-Proof & Water-Proof |
Regulation | CE Marked + RoHS |
Dimensions | 6.8in (172.7mm) Length, 1.44in (36.6mm) Body Diameter |
Cable Length | 5ft, Terminated with IP67 adapter + 1.5ft Flying Lead with IP67 Adapters |
Downloads