THE STENNER S SERIES PUMP INTERFACES WITH PROCESS CONTROL SYSTEMS UTILIZING A 4-20mA OUTPUT SIGNAL AND THREE RELAY OUTPUTS

Built to NEMA 4X for demanding applications. Select from multiple performance indicators and operational modes with intuitive programming and easy navigation. Fine-tune the pump to fit the application; monitor the pump for peace of mind. Prevent unauthorized access to programmed settings with the password protection.

 Built solid, built to last:

  • The Stenner S Series pump uses a strong brushless DC motor equipped with ball bearing support. 
  • Switch mode power supply is very energy efficient. 
  • Totally enclosed motor is outdoor rated.
  •  OLED operation display is easy to see in bright light and easy to navigate it's intuitive programming screens. 
  • QuickPro pump head does not require tools to change a pump tube. 
  • Splined shaft pump head design allows for hight torque and more reliable operation. 
  • NEMA 4X, NSF 61 & 372, cULus indoor/outdoor, CE IP65 Ratings. 

 Maximum Flow Rates: 

  • 40 gpd, up to 100 psi / 151.4 lpd, up to 6.9 bar
  • 85 gpd, up to 25 psi / 321.8 lpd, up to 1.7 bar

 Smart Technology Modes and Indicators:

  • OLED Display
  • Tube Leak Detection
  • Tube Change Timer
  • Standby Mode
  • Repeat Pulse Mode
  • Run Mode
  • Mode Change Interface
  • High and Low Signal Indicator
  • High and Low Flow Indicator
  • Drive Fault Indicator
  • Signal Overrun Indicator
  • Transfer Mode
  • Off Mode

Tube Leak Detection Built Into The Pump Head

  • Detects fluid in the pump head, vertically or horizontally
  • Stops pump on leak detection with alarm relay output
  • Calibrate sensitivity to specific fluid being used. Stops false alarms caused by humidity or substance.

Tube timer:

Set a maintenance interval to let you know when it's time to change the tube before it breaks. 

 Standby Mode: 

Program the transfer mode to activate a relay to start a second Stenner S Series Pump. Great for redundancy and failover should one pump be down for maintenance. 

Signal Inputs: 

  • 4-20 mA Signal: Proportional response to the analog signal, scalable, invertible,speed varies to the input signal
  • 0-10VDC Signal: Proportional response to the analog signal, scalable, invertible,speed varies to the input signal
  • Pulse: Accepts dry contact or open collector input signal from water meter or controllers, activates pump at desired pulse count to run for a specified amount of time. 
  • Hall Effect: Speed varies according to Hall Effect input from flow meter or controller, program based on K factor, process flow range and desired pump output.
  • PPM Feed Constant Flow: Accepts a dry contact or open collector type input signal from flow switch. Program is based on the process flow rate, chemical concentration, chemical specific gravity and the desired ppm feed rate.
  • PPM Feed Variable Flow: Accepts a Hall Effect input from a flow meter. Speed varies based on process flow rate. Program based on K factor, process flow range, chemical concentration, specific gravity and desired ppm feed rate. 

Manual Operation: 

  • Manual: Speed controlled manually. Adjustable from 0% to 100% in 1% increments
  • 7 Day / 24 Hour Timer: Run on a specific day, time of day, at speeds from 1 to 100%. 24 Independent events, any combination of days. 
  • Cycle Timer: Run on a repeating on/off cycle. Set peristaltic pump speed from 1 to 100%

Signal Outputs:

  • 4-20 mA output, produces a non-adjustable signal output that is proportional to the Stenner pump speed percentage the pump is running. 4mA = 0% & 20mA = 100%. 
  • Relays dry contact programed to either normally open or normally closed. Indicate alarms, repeat and incoming signal, transfer operation to another S series pump that is in Standby. 

Customers Also Viewed