Stenner
Stenner
Stenner S Series S30 Models
Checkout securely with:
THE STENNER S SERIES PUMP INTERFACES WITH PROCESS CONTROL SYSTEMS UTILIZING A 4-20mA OUTPUT SIGNAL AND THREE RELAY OUTPUTS
Built to NEMA 4X for demanding applications. Select from multiple performance indicators and operational modes with intuitive programming and easy navigation. Fine-tune the pump to fit the application; monitor the pump for peace of mind. Prevent unauthorized access to programmed settings with the password protection.
Built solid, built to last:
- The Stenner S Series pump uses a strong brushless DC motor equipped with ball bearing support.
- Switch mode power supply is very energy efficient.
- Totally enclosed motor is outdoor rated.
- OLED operation display is easy to see in bright light and easy to navigate it's intuitive programming screens.
- QuickPro pump head does not require tools to change a pump tube.
- Splined shaft pump head design allows for hight torque and more reliable operation.
- NEMA 4X, NSF 61 & 372, cULus indoor/outdoor, CE IP65 Ratings.
Maximum Flow Rates:
- 40 gpd, up to 100 psi / 151.4 lpd, up to 6.9 bar
- 85 gpd, up to 25 psi / 321.8 lpd, up to 1.7 bar
Smart Technology Modes and Indicators:
- OLED Display
- Tube Leak Detection
- Tube Change Timer
- Standby Mode
- Repeat Pulse Mode
- Run Mode
- Mode Change Interface
- High and Low Signal Indicator
- High and Low Flow Indicator
- Drive Fault Indicator
- Signal Overrun Indicator
- Transfer Mode
- Off Mode
Tube Leak Detection Built Into The Pump Head
- Detects fluid in the pump head, vertically or horizontally
- Stops pump on leak detection with alarm relay output
- Calibrate sensitivity to specific fluid being used. Stops false alarms caused by humidity or substance.
Tube timer:
Set a maintenance interval to let you know when it's time to change the tube before it breaks.
Standby Mode:
Program the transfer mode to activate a relay to start a second Stenner S Series Pump. Great for redundancy and failover should one pump be down for maintenance.
Signal Inputs:
- 4-20 mA Signal: Proportional response to the analog signal, scalable, invertible,speed varies to the input signal
- 0-10VDC Signal: Proportional response to the analog signal, scalable, invertible,speed varies to the input signal
- Pulse: Accepts dry contact or open collector input signal from water meter or controllers, activates pump at desired pulse count to run for a specified amount of time.
- Hall Effect: Speed varies according to Hall Effect input from flow meter or controller, program based on K factor, process flow range and desired pump output.
- PPM Feed Constant Flow: Accepts a dry contact or open collector type input signal from flow switch. Program is based on the process flow rate, chemical concentration, chemical specific gravity and the desired ppm feed rate.
- PPM Feed Variable Flow: Accepts a Hall Effect input from a flow meter. Speed varies based on process flow rate. Program based on K factor, process flow range, chemical concentration, specific gravity and desired ppm feed rate.
Manual Operation:
- Manual: Speed controlled manually. Adjustable from 0% to 100% in 1% increments
- 7 Day / 24 Hour Timer: Run on a specific day, time of day, at speeds from 1 to 100%. 24 Independent events, any combination of days.
- Cycle Timer: Run on a repeating on/off cycle. Set peristaltic pump speed from 1 to 100%
Signal Outputs:
- 4-20 mA output, produces a non-adjustable signal output that is proportional to the Stenner pump speed percentage the pump is running. 4mA = 0% & 20mA = 100%.
- Relays dry contact programed to either normally open or normally closed. Indicate alarms, repeat and incoming signal, transfer operation to another S series pump that is in Standby.