Liquid level control

Liquid level control is a system used to control the fluid flow in fluid tanks. These devices are installed in upstream or downstream applications to keep a check on the fluid level. The primary purpose of the liquid level control system is to maintain an appropriate fluid level in large industrial tanks. Cannon Water Technology offers high-quality liquid level control systems for various industrial and commercial applications. We stock liquid level sensors from leading brands like Flowline, APG, Gizmo, and so on. These level controllers have been successfully used on various industrial processing equipment.

Sidebar Sidebar Sidebar
  • Flowline EchoPod UG12 Ultrasonic Level Sensor Flowline EchoPod UG12, Ultrasonic Level Sensor, 39.3' Range

    Flowline

    Flowline EchoPod UG12, Ultrasonic Level Sensor, 39.3' Range

    kr7 287,07 - kr7 632,25
          APPLICATION The general purpose reflective ultrasonic level transmitter provides continuous level measurement up to 39.3’ (12m) with a 4-20 mA analog signal output, and is configured via its integral push button...
    kr7 287,07 - kr7 632,25

  • Tank High/Low Level Alarm PVC/PP

    Gizmo

    Tank High/Low Level Alarm

    kr1 718,98 - kr2 285,07
    x The TANK ALARM grabs attention with a bright flashing LED and a loud beeper when liquid level is too high or too low. Easy to install. Easy to adjust the depth in tank. Stop overfilled or empty tanks for good. It guards against overfilling or...
    kr1 718,98 - kr2 285,07

  • Advantage Controls FILL Liquid Level Alarm Controllers

    Advantage Controls

    Advantage Controls FILL Liquid Level Alarm Controllers

    kr3 298,36 - kr6 550,69
    Application: ALL liquid level alarm controllers preventchemical metering pumps from pumping dry and give an alarm notification of a low chemical level.FILL liquid level alarm controllers automate filling of a tank with a control relay output based on a...
    kr3 298,36 - kr6 550,69

  • Advantage Controls ALL Liquid Level Alarm Controllers

    Advantage Controls

    Advantage Controls ALL Liquid Level Alarm Controllers

    kr2 155,44 - kr4 610,03
    Application: ALL liquid level alarm controllers prevent chemical metering pumps from pumping dry and give an alarm notification of a low chemical level.FILL liquid level alarm controllers automate filling of a tank with a control relay output based on a...
    kr2 155,44 - kr4 610,03

  • Advantage Controls Tank Level Wands

    Advantage Controls

    Advantage Controls Tank Level Wands

    kr1 058,54 - kr1 112,24
    Level WandsALL-S level wands are a low cost float style level switch attached to a rigid PVC wand (various lengths available) with a 2” bung fitting and liquid tight that allows you to set the level switch to a desired tank level...
    kr1 058,54 - kr1 112,24

  • Drum Alarm (Low) Level, Polypropylene Material

    Gizmo

    Drum Alarm (Low) Level, Polypropylene Material

    kr2 140,10 - kr2 830,45
    Demonstration Video: How to configure a drum alarm low level: MONITOR LIQUID LEVEL IN DRUMS when feeding from chemical drums and containers. Quick and easy to install - then forget about drum level forever. Simply connect your feed line and...
    kr2 140,10 - kr2 830,45

  • Level Control |PVC

    SEKO - Beta Technology

    Level Control |PVC

    kr375,32 - kr405,77
    Elastomer free Available with or without foot check valve to avoid emptying of suction tube and loss of product during the changing of tank operation Clips to other probes or to the level control to avert dangerous dry pump dosing.   Level control...
    kr375,32 - kr405,77

  • EchoPod DL34 Ultrasonic Level Sensor

    Flowline

    EchoPod DL34 Ultrasonic Level Sensor with 4 relays, 4-20 mA out, Up to 18' Range

    kr3 796,95 - kr4 103,77
    Description EchoPod DL34, the general purpose, ultrasonic sensor provides non-contact level detection up to 18' (5.5 m) with 4 SPST 60 VA 1A relays and a two-wire 4-20 mA level measurement output. Each relay can be configured on a single set point...
    kr3 796,95 - kr4 103,77

  • EchoPod DL24

    Flowline

    EchoPod DL24

    kr3 260,01 - kr3 643,54
      Description EchoPod DL24, the general purpose, ultrasonic sensor provides non-contact level detection up to 98.4" (2.5m) with 4 SPST 60 VA 1A relays and a two-wire 4-20 mA level measurement output. Each relay can be configured on a single set...
    kr3 260,01 - kr3 643,54

  • Flowline EchoPod DX10-00

    Flowline

    Flowline EchoPod DX10-00

    kr3 421,09 - kr3 977,44
    Description Flowline EchoPod DX10-00 and DX10-01, a general purpose non-contact ultrasonic level transmitter that outputs frequency or voltage for small tanks 49.2" (1.25 m) or less. EchoPod enables flexible design applications for system...
    kr3 421,09 - kr3 977,44

  • Flowline EchoPod DS14-00

    Flowline

    Flowline EchoPod DS14-00

    kr2 876,48 - kr3 221,65
    Description Flowline EchoPod DS14-00 and DS14-01, a general purpose non-contact ultrasonic level sensor switch and controller for small tanks 49.2" (1.25 m) or less. EchoPod enables flexible design applications for system integration or retrofit of...
    kr2 876,48 - kr3 221,65

  • Flowline EchoPod DL10-00 (Flowline DL10-00) Flowline EchoPod DL10-00

    Flowline

    Flowline EchoPod DL10-00

    kr2 282,00 - kr2 615,67
    EchoPod® is an innovative level sensor engineered for use in chemical, water and wastewater applications. These instruments are designed to provide a non-contact continuous level solution, which make them a right choice for small day tank, sump and...
    kr2 282,00 - kr2 615,67

  • FlowLine EchoPod DL14-00 FlowLine EchoPod

    Flowline

    FlowLine EchoPod DL14-00

    kr2 761,42 - kr3 072,08
    FlowLine EchoPod DL 14-01 and DL14-00 is a general purpose ultrasonic level sensor. With this sensor, you get up to 1.25 m (49.2″) of non-contact level detection. In addition to this, it features a two-wire 4-20 mA level measurement output and 4...
    kr2 761,42 - kr3 072,08

  • Level control unit | OPL-Adv

    SEKO - Beta Technology

    Level control unit | OPL-Adv

    kr1 004,23
    Optional, externally mounted, empty product alert system available Fast and safe connections for foot filter and tubing fittings   Specifications- 7 Level control unit Power-supply requirements: Low voltage, supplied from the central unit...
    kr1 004,23

    Add to Cart The item has been added
  • Flowline Thermo-Flo Liquid Flow Switch FT10-1305

    Flowline

    Flowline Thermo-Flo Liquid Flow Switch FT10-1305

    kr1 380,71
      Flowline Thermo-Flo Liquid Flow Switch FT10-1305 Features:  Flowline Thermal Dispersion Flow Switch w/ NPN output 3 Wire, Polarity Reliant Set Point .04 to 3 fps Response Time 1-10 Seconds 12-36 VDC Process Mount: 3/4" NPT
    kr1 380,71

    Add to Cart The item has been added

What is a Liquid Level Controller?

A liquid level controller is an electrical device that monitors the level of the liquid in a fluid tank. The system works by controlling the fluid levels as per the settings done by the operator. When the tank reaches a specific fluid level, it automatically refills the tank.

Components of a Liquid Level Controller

A liquid level controller is composed of crucial components that work together, promoting the system's advanced functioning. These important components are as follows:

  • Measurement System: This is a sensor that helps in sensing the fluid level inside the tank. 
  • Fluid Tank: A large container that contains a desired amount of fluid.
  • Controller: It helps in controlling the liquid level. 
  • Pump: The pump draws water from the water source and transfers it to the tank. The controller usually actuates the pump.

Working of the Liquid Level Controller Explained

These devices feature float or a displacer that is connected to the controller, which senses the level of fluid. This displacer is usually set in the process fluid, where it lies within the separator. The displacer will attain the highest set point when the liquid level increases. A pneumatic or an electric signal is sent to the dump valve, which will open as per the signal. 

The displacer will attain the low set point when the liquid level decreases. The level controller removes the signal to the valve and switches it to the vent. If this happens, the gas inside the valve actor is released through the level controller, and the dump valve closes till it receives the high-level signal.

How to Choose the Right Liquid Level Controller for Your Applications?

We offer various types of liquid level controllers, which may make their selection difficult. Our experts will help you with the right selection. However, the following pointers will be helpful, too.

  • Check for the controller configuration that will work best for your application.
  • Understand the differences and strengths of throttle pilot or snap pilot before choosing the right one for your application. 
  • Focus on the mounting configuration, float size, straight and hang down configuration, and float material.
  • Check if your application requires a pilot, which bleeds out the pilot gas.
  • Identify if the reverse acting level controller is required. 
  • Address your application requirements to find the pressure rating and connection size.

Cannon Water Technology is a one-stop solution for all your water, wastewater, or any fluid treatment needs. Our journey to become the top water treatment specialist in the country was not easy. However, a sharp focus on changing industry trends, attention to client requirements, and understanding of quality products has helped us become a favored choice for all water treatment needs. If you have any questions regarding our liquid level sensors or the buying process, then please feel free to reach out to us. Our customer support team will help you throughout the process.