Lakewood Instruments
Lakewood Instruments
Lakewood Instruments Model 3175 Conductivity Cooling Tower Controller
SKU:
Model 3175 CTW
Weight:
1.00 LBS
Shipping:
Calculated at Checkout
FRw5090742 - FRw12222849
Checkout securely with:
Overview
- Accurately controls boiler and cooling tower conductivity. A standard secondary input may be used to control ORP or pH.
- Easy to program with an intuitive menu to configure for either cooling tower, boiler, or condensate applications with appropriate conductivity sensors.
- Larger 7” responsive touch screen display for quicker setup compared to using a keypad.
- Updated processor for modern connectivity and datalogging.
- Email alarm notifications.
- Reliable circuitry that has been proven for two decades to accurately control your water chemistry.
- User-selected relay options for a high level of application flexibility.
- Configure relays to your preference – for setpoint control, based on water meter, percent of blowdown or percent of time.
- Up to 12 scheduled feeds can be configured for excellent control of your system.
- Affordably priced between our Model 1575e and NexSys water treatment control systems.
Features
- 7” color touchscreen display.
- (5) Output relays with 1 typically used for the bleed/blowdown, plus 4 chemical feeds.
- (2) Water meter inputs
- (2) drum switch inputs
- (1) conductivity input
- (1) flow switch input
- (1) 4-20mA input
- (1) 4-20mA output
- Data logging with onboard historical graphs and .csv file output.
- Ethernet capability.
- Remote communications.
- Email notification of alarm conditions.
- Removable power cord and receptacles for conduit installations. Enclosure is rated NEMA 4X.
- Single circuit board for high reliability and lower cost.
- Large shallow enclosure for easy wiring.
- Ball valve delay feature allows accurate control of motorized ball valves.
Specifications
- Model: 3175
- Conductivity range: 50-10,000 μS
- Conductivity sensor: 2 electrode
- Conductivity Resolution: ± 10 μS (conductivity <5000 μS) / ±100 μS(conductivity > 5000 μS)
- Temperature comp.: 500NTC, NONE
- Accuracy & repeatability: ± 1.0%
- Deadband/Setpoint: Programmable
- Auto/Manual outputs: Menu selectable
- Interface: 7 inch capacitive touchscreen
- Drum Switch Inputs: 2 digital contact inputs
- Water meter inputs (2): Contact head, paddle wheel, or turbine
- Timers: Max. blowdown time exceeded and relay run time exceeded
- Output Signal: One 4 – 20 mA, isolated or non-isolated optionally powered output for conductivity
- Input Signal: One 4-20 mA, non- isolated internally powered input for conductivity
- Output relays: 5, 4 selectable use, 1 blowdown
- Relay ratings: 3A each, 10A total
- Power: 120/240 VAC 50/60 Hz
- Ambient: 32° – 120°F (0 – 49°C)
Downloads
- Quick Start Guide: Model 3175 Water Treatment Controller Ethernet Port Summary & Email Setup
- Quick Start Guide: Model 3175 Water Treatment Controller Micro SD Card Usage & Procedures
- Cutsheet: Model 3175 Water Treatment Controller
Cooling Tower Water Treatment Controller Application