Overview

  • Accurately controls boiler and cooling tower conductivity. A standard secondary input may be used to control ORP or pH.
  • Easy to program with an intuitive menu to configure for either cooling tower, boiler, or condensate applications with appropriate conductivity sensors.
  • Larger 7” responsive touch screen display for quicker setup compared to using a keypad.
  • Updated processor for modern connectivity and datalogging.
  • Email alarm notifications.
  • Reliable circuitry that has been proven for two decades to accurately control your water chemistry.
  • User-selected relay options for a high level of application flexibility.
  • Configure relays to your preference – for setpoint control, based on water meter, percent of blowdown or percent of time.
  • Up to 12 scheduled feeds can be configured for excellent control of your system.
  • Affordably priced between our Model 1575e and NexSys water treatment control systems.

Features

  • 7” color touchscreen display.
  • (5) Output relays with 1 typically used for the bleed/blowdown, plus 4 chemical feeds.
  • (2) Water meter inputs
  • (2) drum switch inputs
  • (1) conductivity input
  • (1) flow switch input
  • (1) 4-20mA input
  • (1) 4-20mA output
  • Data logging with onboard historical graphs and .csv file output.
  • Ethernet capability.
  • Remote communications.
  • Email notification of alarm conditions.
  • Removable power cord and receptacles for conduit installations. Enclosure is rated NEMA 4X.
  • Single circuit board for high reliability and lower cost.
  • Large shallow enclosure for easy wiring.
  • Ball valve delay feature allows accurate control of motorized ball valves.

Specifications

  • Model: 3175
  • Conductivity range: 50-10,000 μS
  • Conductivity sensor: 2 electrode
  • Conductivity Resolution: ± 10 μS (conductivity <5000 μS) / ±100 μS(conductivity > 5000 μS)
  • Temperature comp.: 500NTC, NONE
  • Accuracy & repeatability: ± 1.0%
  • Deadband/Setpoint: Programmable
  • Auto/Manual outputs: Menu selectable
  • Interface: 7 inch capacitive touchscreen
  • Drum Switch Inputs: 2 digital contact inputs
  • Water meter inputs (2): Contact head, paddle wheel, or turbine
  • Timers: Max. blowdown time exceeded and relay run time exceeded
  • Output Signal: One 4 – 20 mA, isolated or non-isolated optionally powered output for conductivity
  • Input Signal: One 4-20 mA, non- isolated internally powered input for conductivity
  • Output relays: 5, 4 selectable use, 1 blowdown
  • Relay ratings: 3A each, 10A total
  • Power: 120/240 VAC 50/60 Hz
  • Ambient: 32° – 120°F (0 – 49°C)